IR Receiver Modules for Remote Control Systems
The TSOP22.., TSOP48.., TSOP24.. and TSOP44.. series are miniaturized IR receiver modules designed for infrared remote control systems. They integrate a PIN diode and a preamplifier on a lead frame, with an IR filter within the epoxy package. These modules offer improved immunity to HF, RF, and optical noise, low supply current, and an internal filter for PCM frequency. They are suitable for direct connection to microprocessors for decoding and are optimized to suppress spurious pulses from Wi-Fi and CFL sources. The TSOP24../TSOP44.. series is recommended for new designs due to its newer AGC4, while the TSOP22../TSOP48.. series is provided for compatibility with older AGC2 designs. These components are not qualified according to automotive specifications.
Product Attributes
- Brand: Vishay Semiconductors
- Material Categorization: For definitions of compliance please see www.vishay.com/doc?99912
Technical Specifications
| Part Number | AGC | Carrier Frequency | Pinning | Dimensions (mm) | Mounting | Application | Best Remote Control Code |
| TSOP4830 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 30 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2230 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 30 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP4430 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 30 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | RC-5 |
| TSOP2430 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 30 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | RC-5 |
| TSOP4833 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 33 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2233 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 33 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP4433 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 33 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | RC-6 |
| TSOP2433 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 33 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | RC-6 |
| TSOP4836 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 36 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2236 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 36 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2436 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 36 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | Panasonic |
| TSOP4838 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 38 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2238 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 38 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP4438 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 38 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | NEC |
| TSOP2438 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 38 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | NEC |
| TSOP4840 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 40 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2240 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 40 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP4440 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 40 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | Sharp |
| TSOP2440 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 40 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | Sharp |
| TSOP4856 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 56 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP2256 | LEGACY, FOR LONG BURST REMOTE CONTROLS (AGC2) | 56 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Remote control | |
| TSOP4456 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 56 kHz | 1 = OUT, 2 = GND, 3 = VS | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | r-step |
| TSOP2456 | RECOMMENDED FOR LONG BURST CODES (AGC4) | 56 kHz | 1 = OUT, 2 = VS, 3 = GND | 6.0 W x 6.95 H x 5.6 D | Leaded | Best remote control code | r-step |
2410121733_VISHAY-TSOP4833_C145228.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible