Product Overview
The Unictron A300A Air Transducer is an ultrasonic transducer operating at approximately 300 kHz, designed for both signal transmission and reception. It excels in applications such as double-layer detection, edge detection, web guiding, splice detection, label detection, and proximity measurement. This versatile transducer reliably detects a wide range of materials including paper, glass, transparent plastics, shiny metal, and cardboard.
Product Attributes
- Brand: Unictron Technologies Corporation
- Model Name: A300A
- Part Number: H2KA300KA1CD00
- Transducer Type: Air transducer
- Frequency: 300 kHz
- Construction: Composite PZT-Air System
- Functionality: Transmitter & Receiver in one unit (Double)
Technical Specifications
| Specification | Details |
|---|---|
| Operation frequency | 300 kHz |
| Overall sensitivity | min. 1.8 Vp-p |
| Capacitance (@ 1kHz, 1Vrms) | 1300 20% pF |
| Directivity (half angle @-6 dB) | 5 Degrees |
| Maximum driving voltage | 50 Vp-p |
| Insulation Resistance (@ 100V DC) | 100 (min.) Mega Ohm |
| Operating Temperature | -20C to +70C |
| Storage Temperature | -30C to +70C |
| Storage Relative Humidity | 30-80% |
| Soldering Temperature (Max) | 360C |
| Soldering Time (Max) | 3 seconds |
| Inner box dimensions | 249 x 85 x 111 mm |
| Inner box quantity | 540 pcs (90 pcs x 6 holders) |
| Outer box dimensions | 445 x 260 x 238 mm |
| Outer box quantity | 5400 pcs (10 inner boxes) |
Marking:
- Year code (Y): A ~ Z
- Month code (M): A ~ M (I & O not involved)
- Lot ID (serial number): XX XX
Note on Piezoelectricity: Piezoceramic materials may lose piezoelectric properties due to depolarization when exposed to high temperature or high voltage.
Note on Soldering: Transducer is not designed for reflow soldering. Do not use reflow ovens.
Note on Electric Connection: Do not connect transducer to DC voltage.
Note on Installation: Protect transducer with buffer material at installation to prevent noise induction from vibration.
Note on Water-proof: Not a water-proof device. Avoid exposure to water, organic solvents, and corrosive gases. Keep surface clean; do not touch with skin or clean with organic solvents.
2412091048_Unictron-H2KA300KA1CD00_C5649092.pdf