The SCW8916 is a 4-channel high-sensitivity capacitive water level detection IC capable of accurately detecting changes in water and other liquid levels from a distance of 2mm. It features industrial-grade specifications with 4KV EFT and 6KV contact ESD capabilities, and can pass 3V CS testing, making it an ideal choice for electronic liquid level detection solutions. It is well-suited for water-related home appliances and electronic products such as water dispensers, purifiers, coffee machines, kettles, dishwashers, and ice makers.

Product Attributes

  • Brand: SinOne Chip
  • Origin: (Shenzhen Saiyuan Microelectronics Co., Ltd.)
  • Certifications: 4KV EFT, 6KV Contact ESD, 3V CS Test Passed

Technical Specifications

FeatureSpecification
Working Voltage3.0V~5.5V
Working Temperature-40 ~ 85
PackageSOP16
Water Level Detection Channels1~4 Channels
Sensitivity Adjustment8 levels (adjustable via external resistor)
Test ModeOnline whole-machine water/no-water status debugging
Detection PrincipleCapacitive sensing, non-contact detection up to 2mm
Communication ProtocolsLevel one-to-one output mode, UART output mode
UART Baud Rate9600
UART Output Interval100ms
ESD Capability6KV Contact ESD
EFT Capability4KV EFT
CS Test3V Dynamic CS Test Passed
Channel UsageCH1 (lowest), CH2, CH3, CH4 (highest); unused channels to be grounded.
Sensitivity Resistor100K to VDD for default sensitivity; range from 3.3K to 82K for adjustment.
Output Modes (OUTS Pin)0: UART output (100ms refresh); H (High/Floating): Level one-to-one output.
Test Mode (TOPT Pin)0: Calibrate lower water level only; 1: Calibrate upper and lower water levels.
Self-Check Mode EntryTEST pin receives 500mS low pulse and >500mS high pulse within 2S of power-up.
Calibration Signal (TEST Pin)100mS low pulse + >500ms high for lower water level calibration; two 100mS low pulses + >500ms high for upper and lower water level calibration.