Specifications
Standby Current:
-
working temperature:
-20℃~+70℃
Current Range:
100A~4kA
Voltage - Supply:
24V
Sensitivity:
-
Mfr. Part #:
2904921
Key Attributes
Model Number: 2904921
Product Description

PACT RCP-4000A-1A-D95 - Current Transformer

This set includes a 1 A measuring transducer and a Rogowski coil with a signal line, designed for measuring AC current on busbars and power lines. The Rogowski coil has a length of 300 mm and a diameter of 95 mm, with a 3 m signal line. It is suitable for applications requiring accurate AC current measurement in various industrial settings.

Product Attributes

  • Brand: Phoenix Contact
  • Certifications: UL 61010 Recognized (USA/Canada), UL 508 Listed (USA/Canada), EAC Ex, IEC 61010-1, IEC 61010-2-032
  • Material (Coil): Elastollan
  • Material (Transducer Housing): PC
  • Material (Signal Line Conductor): tinned
  • Insulation: double insulation
  • Origin: Germany (implied by address)

Technical Specifications

SpecificationMeasuring CoilMeasuring Transducer
Dimensions (W x H x D)-22.5 mm x 85 mm x 70.4 mm
Ambient Temperature (Operation)-30 C ... 80 C-20 C ... 70 C
Ambient Temperature (Storage/Transport)-40 C ... 80 C-25 C ... 85 C
Maximum Altitude< 2000 m
Permissible Humidity (Operation)5 % ... 95 % (non-condensing)
Degree of ProtectionIP67 (not assessed by UL)IP20
Nominal Supply Voltage-24 V DC -20 % ... +25 % (19.2 V DC ... 30 V DC)
Max. Current Consumption-190 mA (at 19.2 V)
Power Consumption-4 W
Frequency Measuring Range40 Hz ... 20000 Hz-
Position Error< 1 %
Linearity Error0.1 %< 0.5 % (From the range end value)
Phase Angle< 1
Max. Distances for Copper Cables (PN)32 m (0.75 mm), 64 m (1.5 mm), 107 m (2.5 mm)
Input Signal (at 50 Hz)-100 mV (1000 A)
Input Impedance-27 k (smallest measuring range)
Output Signal (at 50 Hz)100 mV (no load, at 1,000 A)-
Output Voltage (in no-load operation)VOUT = M * dI/dt-
Output Voltage (sinusoidal, no-load)100 mV (VOUT = 2 * * M * f * I (M = 0.318 H; example: At 50 Hz; I = 1,000 A))-
Current Output Signal-0 A AC ... 1 A
Rated Power-1.5 VA
Load-0 ... 1.5
Length of Measuring Coil300 mm-
Diameter of Measuring Coil8.3 mm 0.2 mm-
Length of Signal Cable3000 mm-
Signal Line Conductor Structure2x 0.22 mm (Signal), 1x 0.22 mm (Shielding)-
Rated Insulation Voltage1000 V AC (rms CAT III), 600 V AC (rms CAT IV)-
Test Voltage10.45 kV (DC / 1 min.)1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
Basic Accuracy< 0.21 %-
Frequency Range-45 Hz ... 65 Hz
Max. Detectable Harmonics-< 2 kHz
Connection Method (Transducer Side)-Screw connection
Stripping Length-7 mm
Screw Thread-M3
Conductor Cross Section (Solid)-0.2 mm ... 2.5 mm
Conductor Cross Section (Flexible)-0.2 mm ... 2.5 mm
Conductor Cross Section (AWG)-24 ... 14
Torque-0.5 Nm ... 0.6 Nm
Pollution Degree2
Overvoltage CategoryIII (1000 V), IV (600 V)
Temperature Coefficients0.005 %/K (+10 C ... +70 C), 0.07 %/K (-20C ... +10C)