Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904923 designed for accurate AC current measurement on busbars factory
<
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904923 designed for accurate AC current measurement on busbars factory
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904923 designed for accurate AC current measurement on busbars factory
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904923 designed for accurate AC current measurement on busbars factory
>
Specifications
Standby Current:
-
working temperature:
-20℃~+70℃
Current Range:
100A~4kA
Voltage - Supply:
24V
Sensitivity:
-
Mfr. Part #:
2904923
Key Attributes
Model Number: 2904923
Product Description

Product Overview

Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. The Rogowski coil measures the AC current of busbars and power lines. Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 3 m.

Product Attributes

  • Brand: Phoenix Contact
  • Origin: Germany
  • Certifications: UL 61010 Recognized, UL 508 Listed, EAC

Technical Specifications

PACT RCP-4000A-1A-D190
Dimensions
Width22.5 mm
Height85 mm
Depth70.4 mm
Ambient Conditions
Ambient temperature (operation)-30 C ... 80 C (Measuring coil)
-20 C ... 70 C (Measuring transducer)
Ambient temperature (storage/transport)-40 C ... 80 C (Measuring coil)
-25 C ... 85 C (Measuring transducer)
Maximum altitude< 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Degree of protection (Measuring coil)IP67 (not assessed by UL)
Degree of protection (Measuring transducer)IP20
Measuring transducer supply
Nominal supply voltage24 V DC -20 % ... +25 %
Nominal supply voltage range19.2 V DC ... 30 V DC
Max. current consumption190 mA
Power consumption4 W
Measuring coil input data
Frequency measuring range40 Hz ... 20000 Hz
Position error< 1 %
Linearity error0.1 %
Measuring transducer input data
Measuring ranges (current)100 A, 250 A, 400 A, 630 A, 1000 A, 1500 A, 2000 A, 4000 A
Configurable/programmableVia DIP switches
Phase angle< 1
Max. distances for copper cables at PN32 m (0.75 mm (AWG 20))
64 m (1.5 mm (AWG 16))
107 m (2.5 mm (AWG 14))
Measuring transducer signal input
Input signal (at 50 Hz)100 mV (1000 A)
Input impedance27 k (smallest measuring range)
Measuring coil signal output
Output signal (at 50 Hz)100 mV (no load, at 1,000 A)
Output voltage (in no-load operation)VOUT = M * dI/dt
Output voltage (sinusoidal, in no-load operation)100 mV (VOUT = 2 * * M * f * I (M = 0.318 H; example: At 50 Hz; I = 1,000 A))
Measuring transducer signal output
Current output signal0 A AC ... 1 A
Rated power1.5 VA
Load0 ... 1.5
General data, measuring coil
Length of measuring coil600 mm
Diameter of measuring coil8.3 mm 0.2 mm
Length of signal cable3000 mm
Conductor structure signal line2x 0.22 mm (Signal (tinned))
1x 0.22 mm (Shielding (tinned))
Coil materialElastollan
Housing materialPC
Insulationdouble insulation
Rated insulation voltage1000 V AC (rms CAT III)
600 V AC (rms CAT IV)
Test voltage10.45 kV (DC / 1 min.)
Basic accuracy< 0.21 %
General data for measuring transducer
Linearity error< 0.5 % (From the range end value)
Maximum transmission error 0.5 % (From the range end value)
Frequency range45 Hz ... 65 Hz
Max. detectable harmonics< 2 kHz
Current consumption< 190 mA (at 19.2 V)
Housing materialPolyamide
Test voltage1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
Operating voltage displayGreen LED
General data
Standards/regulationsIEC 61010-1, IEC 61010-2-032
Insulationdouble insulation
Temperature coefficients0.005 %/K (+10 C ... +70 C, both components have the same ambient temperature)
0.07 %/K (-20C ... +10C; both components have the same ambient temperature)
Typical measuring error< 1 %
Connection data
Connection nameMeasuring transducer side
Connection methodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section solid0.2 mm ... 2.5 mm
Conductor cross section flexible0.2 mm ... 2.5 mm
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm
Standards and Regulations
Standards/regulationsIEC 61010-1, IEC 61010-2-032
Insulationdouble insulation
Pollution degree2
Overvoltage categoryIII (1000 V, to neutral conductor)
IV (600 V, to neutral conductor)
Environmental Product Compliance
REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
Classifications
eCl@ss10.0.1: 27210902, 11.0: 27210902, 4.0: 27210900, 4.1: 27210900, 5.0: 27210900, 5.1: 27210900, 6.0: 27210900, 7.0: 27210902, 9.0: 27210902
ETIM3.0: EC002048, 4.0: EC002048, 5.0: EC002048, 6.0: EC002048, 7.0: EC002048
UNSPSC13.2: 39121032, 18.0: 39121032, 19.0: 39121032, 20.0: 39121032, 21.0: 39121032
Approvals
ApprovalsEAC Ex
Approval detailsEAC RU*DE*08.B.01187/19

2411271951_Phoenix-Contact-2904923_C1574401.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max