Specifications
Standby Current:
-
working temperature:
-20℃~+70℃
Current Range:
100A~4kA
Voltage - Supply:
24V
Sensitivity:
-
Mfr. Part #:
2904923
Key Attributes
Model Number:
2904923
Product Description
Product Overview
Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. The Rogowski coil measures the AC current of busbars and power lines. Length of Rogowski coil: 600 mm, diameter: 190 mm. Length of signal line: 3 m.
Product Attributes
- Brand: Phoenix Contact
- Origin: Germany
- Certifications: UL 61010 Recognized, UL 508 Listed, EAC
Technical Specifications
| PACT RCP-4000A-1A-D190 | |
| Dimensions | |
| Width | 22.5 mm |
| Height | 85 mm |
| Depth | 70.4 mm |
| Ambient Conditions | |
| Ambient temperature (operation) | -30 C ... 80 C (Measuring coil) -20 C ... 70 C (Measuring transducer) |
| Ambient temperature (storage/transport) | -40 C ... 80 C (Measuring coil) -25 C ... 85 C (Measuring transducer) |
| Maximum altitude | < 2000 m |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Degree of protection (Measuring coil) | IP67 (not assessed by UL) |
| Degree of protection (Measuring transducer) | IP20 |
| Measuring transducer supply | |
| Nominal supply voltage | 24 V DC -20 % ... +25 % |
| Nominal supply voltage range | 19.2 V DC ... 30 V DC |
| Max. current consumption | 190 mA |
| Power consumption | 4 W |
| Measuring coil input data | |
| Frequency measuring range | 40 Hz ... 20000 Hz |
| Position error | < 1 % |
| Linearity error | 0.1 % |
| Measuring transducer input data | |
| Measuring ranges (current) | 100 A, 250 A, 400 A, 630 A, 1000 A, 1500 A, 2000 A, 4000 A |
| Configurable/programmable | Via DIP switches |
| Phase angle | < 1 |
| Max. distances for copper cables at PN | 32 m (0.75 mm (AWG 20)) 64 m (1.5 mm (AWG 16)) 107 m (2.5 mm (AWG 14)) |
| Measuring transducer signal input | |
| Input signal (at 50 Hz) | 100 mV (1000 A) |
| Input impedance | 27 k (smallest measuring range) |
| Measuring coil signal output | |
| Output signal (at 50 Hz) | 100 mV (no load, at 1,000 A) |
| Output voltage (in no-load operation) | VOUT = M * dI/dt |
| Output voltage (sinusoidal, in no-load operation) | 100 mV (VOUT = 2 * * M * f * I (M = 0.318 H; example: At 50 Hz; I = 1,000 A)) |
| Measuring transducer signal output | |
| Current output signal | 0 A AC ... 1 A |
| Rated power | 1.5 VA |
| Load | 0 ... 1.5 |
| General data, measuring coil | |
| Length of measuring coil | 600 mm |
| Diameter of measuring coil | 8.3 mm 0.2 mm |
| Length of signal cable | 3000 mm |
| Conductor structure signal line | 2x 0.22 mm (Signal (tinned)) 1x 0.22 mm (Shielding (tinned)) |
| Coil material | Elastollan |
| Housing material | PC |
| Insulation | double insulation |
| Rated insulation voltage | 1000 V AC (rms CAT III) 600 V AC (rms CAT IV) |
| Test voltage | 10.45 kV (DC / 1 min.) |
| Basic accuracy | < 0.21 % |
| General data for measuring transducer | |
| Linearity error | < 0.5 % (From the range end value) |
| Maximum transmission error | 0.5 % (From the range end value) |
| Frequency range | 45 Hz ... 65 Hz |
| Max. detectable harmonics | < 2 kHz |
| Current consumption | < 190 mA (at 19.2 V) |
| Housing material | Polyamide |
| Test voltage | 1.5 kV AC (Supply/input and output: 50 Hz, 1 min) |
| Operating voltage display | Green LED |
| General data | |
| Standards/regulations | IEC 61010-1, IEC 61010-2-032 |
| Insulation | double insulation |
| Temperature coefficients | 0.005 %/K (+10 C ... +70 C, both components have the same ambient temperature) 0.07 %/K (-20C ... +10C; both components have the same ambient temperature) |
| Typical measuring error | < 1 % |
| Connection data | |
| Connection name | Measuring transducer side |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm ... 2.5 mm |
| Conductor cross section flexible | 0.2 mm ... 2.5 mm |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
| Standards and Regulations | |
| Standards/regulations | IEC 61010-1, IEC 61010-2-032 |
| Insulation | double insulation |
| Pollution degree | 2 |
| Overvoltage category | III (1000 V, to neutral conductor) IV (600 V, to neutral conductor) |
| Environmental Product Compliance | |
| REACh SVHC | Lead 7439-92-1 |
| China RoHS | Environmentally Friendly Use Period = 50 years |
| Classifications | |
| eCl@ss | 10.0.1: 27210902, 11.0: 27210902, 4.0: 27210900, 4.1: 27210900, 5.0: 27210900, 5.1: 27210900, 6.0: 27210900, 7.0: 27210902, 9.0: 27210902 |
| ETIM | 3.0: EC002048, 4.0: EC002048, 5.0: EC002048, 6.0: EC002048, 7.0: EC002048 |
| UNSPSC | 13.2: 39121032, 18.0: 39121032, 19.0: 39121032, 20.0: 39121032, 21.0: 39121032 |
| Approvals | |
| Approvals | EAC Ex |
| Approval details | EAC RU*DE*08.B.01187/19 |