Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904922 for industrial AC current monitoring factory
<
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904922 for industrial AC current monitoring factory
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904922 for industrial AC current monitoring factory
quality Measuring transducer and Rogowski coil set Phoenix Contact 2904922 for industrial AC current monitoring factory
>
Specifications
Standby Current:
-
working temperature:
-20℃~+70℃
Current Range:
100A~4kA
Voltage - Supply:
24V
Sensitivity:
-
Mfr. Part #:
2904922
Key Attributes
Model Number: 2904922
Product Description

Product Overview

Set consisting of one 1 A measuring transducer and one Rogowski coil with signal line. The Rogowski coil measures the AC current of busbars and power lines. Features a 450 mm length and 140 mm diameter Rogowski coil with a 3 m signal line.

Product Attributes

  • Brand: Phoenix Contact
  • Origin: Germany
  • Certifications: UL, USA/Canada UL 61010 Recognized, UL 508 Listed, EAC Ex

Technical Specifications

SpecificationValue
Dimensions (Width)22.5 mm
Dimensions (Height)85 mm
Dimensions (Depth)70.4 mm
Ambient Temperature (Operation - Measuring coil)-30 C ... 80 C
Ambient Temperature (Operation - Measuring transducer)-20 C ... 70 C
Ambient Temperature (Storage/Transport - Measuring coil)-40 C ... 80 C
Ambient Temperature (Storage/Transport - Measuring transducer)-25 C ... 85 C
Maximum Altitude< 2000 m
Permissible Humidity (Operation)5 % ... 95 % (non-condensing)
Measuring Coil Degree of ProtectionIP67 (not assessed by UL)
Measuring Transducer Degree of ProtectionIP20
Nominal Supply Voltage24 V DC -20 % ... +25 %
Nominal Supply Voltage Range19.2 V DC ... 30 V DC
Max. Current Consumption190 mA
Power Consumption4 W
Frequency Measuring Range40 Hz ... 20000 Hz
Position Error< 1 %
Linearity Error (Measuring Coil)0.1 %
Measuring Ranges (Current)100 A, 250 A, 400 A, 630 A, 1000 A, 1500 A, 2000 A, 4000 A
Configurable/ProgrammableVia DIP switches
Phase Angle< 1
Max. Distances for Copper Cables at PN32 m (0.75 mm (AWG 20)), 64 m (1.5 mm (AWG 16)), 107 m (2.5 mm (AWG 14))
Input Signal (at 50 Hz)100 mV (1000 A)
Input Impedance27 k (smallest measuring range)
Output Signal (at 50 Hz)100 mV (no load, at 1,000 A)
Output Voltage (in no-load operation)VOUT = M * dI/dt
Output Voltage (sinusoidal, in no-load operation)100 mV (VOUT = 2 * * M * f * I (M = 0.318 H; example: At 50 Hz; I = 1,000 A))
Current Output Signal0 A AC ... 1 A
Rated Power1.5 VA
Load0 ... 1.5
Length of Measuring Coil450 mm
Diameter of Measuring Coil8.3 mm 0.2 mm
Length of Signal Cable3000 mm
Conductor Structure Signal Line2x 0.22 mm (Signal (tinned)), 1x 0.22 mm (Shielding (tinned))
Coil MaterialElastollan
Housing Material (Measuring Coil)PC
InsulationDouble insulation
Rated Insulation Voltage1000 V AC (rms CAT III), 600 V AC (rms CAT IV)
Test Voltage (Measuring Coil)10.45 kV (DC / 1 min.)
Basic Accuracy (Measuring Coil)< 0.21 %
Linearity Error (Measuring Transducer)< 0.5 % (From the range end value)
Maximum Transmission Error 0.5 % (From the range end value)
Frequency Range (Measuring Transducer)45 Hz ... 65 Hz
Max. Detectable Harmonics< 2 kHz
Current Consumption (Measuring Transducer)< 190 mA (at 19.2 V)
Housing Material (Measuring Transducer)Polyamide
Test Voltage (Measuring Transducer)1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
Operating Voltage DisplayGreen LED
Standards/RegulationsIEC 61010-1, IEC 61010-2-032
Insulation (General)Double insulation
Temperature Coefficients0.005 %/K (+10 C ... +70 C), 0.07 %/K (-20C ... +10C)
Connection Method (Measuring Transducer Side)Screw connection
Stripping Length7 mm
Screw ThreadM3
Conductor Cross Section (Solid)0.2 mm ... 2.5 mm
Conductor Cross Section (Flexible)0.2 mm ... 2.5 mm
Conductor Cross Section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm
Pollution Degree2
Overvoltage CategoryIII (1000 V, to neutral conductor), IV (600 V, to neutral conductor)
REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
eCl@ss10.0.1: 27210902, 11.0: 27210902, 4.0: 27210900, 4.1: 27210900, 5.0: 27210900, 5.1: 27210900, 6.0: 27210900, 7.0: 27210902, 9.0: 27210902
ETIM3.0: EC002048, 4.0: EC002048, 5.0: EC002048, 6.0: EC002048, 7.0: EC002048
UNSPSC13.2: 39121032, 18.0: 39121032, 19.0: 39121032, 20.0: 39121032, 21.0: 39121032
ApprovalsEAC Ex, EAC RU*DE*08.B.01187/19

2411272152_Phoenix-Contact-2904922_C1574404.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max