Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Nyfea FHTC3 TR Sensor IC for Accurate Temperature and Humidity Measurement in Compact Package factory
<
quality Nyfea FHTC3 TR Sensor IC for Accurate Temperature and Humidity Measurement in Compact Package factory
>
Specifications
Humidity Tolerance:
±3%RH
Temperature Range:
-45℃~+130℃
Resolution:
-
Humidity:
0%RH~100%RH
Temperature Tolerance:
±0.3℃
Mfr. Part #:
FHTC3-TR
Package:
DFN-6(2x2)
Key Attributes
Model Number: FHTC3-TR
Product Description

Product Overview

The FHTC3 is a miniature, ultra-low power temperature and humidity sensor IC designed for consumer electronics applications. It integrates a complete sensing system on a single chip, including capacitive humidity sensing, PN junction temperature measurement, a 16-bit ADC, digital signal processing, calibration data storage, and an I2C digital communication interface. Its compact DFN6 package (2x2x0.75mm) makes it ideal for space-constrained designs. The FHTC3 offers wide supply voltage (1.6V-5.5V) and measurement ranges, factory calibration, and reflow solderability, making it suitable for applications like cold chain transportation, smart homes, smart agriculture, and communication equipment.

Product Attributes

  • Brand: Nyfea
  • Part Number: FHTC3
  • Package: DFN6 (2x2x0.75mm)
  • Calibration: Factory calibrated
  • Solderability: Reflow solderable
  • Packaging: Tape and reel

Technical Specifications

ParameterConditionValueUnitComments
Sensor Performance
Humidity AccuracyTyp.3.0%RHMax. See Figure 3
Humidity Resolution-0.01%RH-
Humidity Hysteresis-1.0%RH-
Humidity Specified Range-0-100%RH-
Humidity Response Time63%8s-
Humidity Long-term driftTyp.<0.5%RH/y-
Temperature AccuracyTyp.0.3Max. See Figure 5
Temperature Resolution-0.01-
Temperature Hysteresis-1.0-
Temperature Specified Range--45 to +130-
Temperature Response Time63%< 5-30s-
Temperature Long-term driftTyp.<0.02C /y-
Electrical Characteristic Parameters (@25, 3.3V)
Supply voltageVDD1.6 - 5.5V-
Power-up levelVPOR1.3 - 1.5VStatic power supply
Supply current (Idle state)IDD45 - 80AAfter power-up, sensor remains in idle state unless a sleep or measurement command is sent
Supply current (Sleep mode)IDD0.2 - 0.3ARequires a wake-up command
Supply current (Measurement Normal)IDD500 - 860AAverage current consumption while measuring
Supply current (Measurement Low power)IDD320 - 620AAverage current consumption while measuring
Average current consumption (continuous operation, 1 measurement/sec)IDD3ANormal
Average current consumption (continuous operation, 1 measurement/sec)IDD1ALow power
Absolute Maximum Ratings
Supply voltage--0.3 to +6V-
Operating temperature range--45 to 130-
Storage temperature range--45 to 130-
ESD HBM (human body mode)--4 to +4kV-
ESD CDM (charge device mode)--500 to +500V-
Latch up, JESD78 Class , 125C--100 to +100mA-
Sensor System Timings (@ 25, 3.3V)
Power-up timetPU180 - 500sAfter hard reset, VDD > VPOR
Soft reset timetSR180 - 500sAfter soft reset ACK, sensor enters idle state
Measurement duration (Normal)tMEAS10 - 11msHumidity and temperature measurement
Measurement duration (Low power)tMEAS1.5 - 2msHumidity and temperature measurement
Communication Timings (@ 25, 3.3V)
SCL clock frequency (Normal)fSCL0 - 100KHz-
SCL clock frequency (Low Power)fSCL0 - 1000KHz-
Hold time START conditiontHD;STA4.0usNormal mode
Hold time START conditiontHD;STA0.6usLow Power mode
Low period of SCL clocktLOW4.5usNormal mode
Low period of SCL clocktLOW0.5usLow Power mode
High period of SCL clocktHIGH4.0usNormal mode
High period of SCL clocktHIGH0.26usLow Power mode
Set-up time for repeated START conditiontSU;STA4.7usNormal mode
Set-up time for repeated START conditiontSU;STA0.5usLow Power mode
SDA hold timetHD;DAT0us-
SDA set-up timetSU;DAT250nsNormal mode
SDA set-up timetSU;DAT50nsLow Power mode
SCL/SDA rise timetR1000nsNormal mode
SCL/SDA rise timetR120nsLow Power mode
SCL/SDA fall timetF300nsNormal mode
SCL/SDA fall timetF120nsLow Power mode
SDA valid timetVD:DAT3.5usNormal mode
SDA valid timetVD:DAT0.5usLow Power mode
Set-up time for STOP conditiontSU:STO4usNormal mode
Set-up time for STOP conditiontSU:STO0.26usLow Power mode
Capacitive load on bus lineCB500pFNormal mode
Capacitive load on bus lineCB400pFLow Power mode

2509101515_Nyfea-FHTC3-TR_C51901044.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max