OMRON Clean Sensing System ZN Series
Product Overview
The OMRON Clean Sensing System ZN Series offers advanced clean-monitoring solutions for manufacturing environments, including electronic component production, multi-clean control cells, direct clean control, and storage of precision and optical components. These localized, continuous clean-monitoring systems are designed to improve quality and enable comprehensive reporting by integrating sensing and control capabilities. They provide constant monitoring of particle volume and air volume, ensuring optimum clean environments through features like rapid ventilation, energy-conserving gradational air control, and HEPA filtration. The system is ideal for maintaining cleanliness in clean booths, inspection, and measurement environments, addressing the question of whether a filtered booth is truly clean by tying clean measures to quality.
Product Attributes
- Brand: OMRON
- Series: ZN Series
Technical Specifications
Air Clean Units
| Model | Air Outlet Dimension | Particle Outlet Efficiency | Air Volume (m/min) | Sound Noise Level (dBA) | Main Filter | Power Supply Voltage | Dimensions (mm) (WDH) | Weight (Approx.) |
|---|---|---|---|---|---|---|---|---|
| ZN-A2502/A2502D | 225 205 mm | >99.99% for 0.3-m particles | 0.3 to 1.8 (typical) | Level 3: 53 dB (typical) Level 1: 41 dB (typical) | HEPA filter (ZN9-AHP25) | 24 VDC 10% | 250 250 97.5 mm | 2 kg |
| ZN-A4105/A4105D | 360 360 mm | >99.99% for 0.3-m particles | 1.0 to 5.0 (typical) | Level 3: 53 dB (typical) Level 1: 40 dB (typical) | HEPA filter (ZN9-AHP41) | 24 VDC 10% | 410 410 129.5 mm | 5.2 kg |
Ionizers
| Model | Applicable Air Clean Units | Power Supply Voltage | Current Consumption | Output Voltage (max.) | Discharge Method | Dimensions (mm) (WDH) | Weight (Approx.) |
|---|---|---|---|---|---|---|---|
| ZN-J25A | ZN-A2502 | 24 VDC 10% | 300 mA max. | 7 kV max. | Variable DC | 248 310 45 mm | 0.6 kg |
| ZN-J41A | ZN-A4105 | 24 VDC 10% | 300 mA max. | 7 kV max. | Variable DC | 408 470 45 mm | 1.5 kg |
Air Particle Sensors
| Model | Sensor Head Model | Applicable Amplifier | Measurement Method | Light Source | Applicable Particle Size | Connection Method | Weight (Approx.) |
|---|---|---|---|---|---|---|---|
| ZN-PD03 | ZN-PD03 | ZN-PDA11/ZN-PDA12 | 90 sideways light-scattering | Semiconductor laser | 0.3, 0.5, or 1.0 m min. | Connector cable (0.5 m standard) | 300 g |
Amplifiers
| Model | Sampling Time | Average Count Setting | Power Supply Voltage | Current Consumption | Connection Method | Weight (Approx.) |
|---|---|---|---|---|---|---|
| ZN-PDA11 | 1 to 599 s (selectable) | 1, 2, 4, 8, 16, 32, or 64 | 24 VDC 10% | 300 mA max. | Cable (2 m standard) | 180 g |
| ZN-PDA12 | 1 to 599 s (selectable) | 1, 2, 4, 8, 16, 32, or 64 | 24 VDC 10% (Supplied from Air Clean Unit) | 300 mA max. | Connector cable (2 m standard) | 180 g |
Interface Units
| Model | Power Supply Voltage | Current Consumption | Connection Method | Weight (Approx.) |
|---|---|---|---|---|
| ZN-SFW11 | Supplied from ZN-PDA | 45 mA max. (with 24-VDC power) | Connector cable (2 m standard) | 100 g |
| ZN-SFW12 | Supplied from ZN-PDA | 45 mA max. (with 24-VDC power) | Connector cable (2 m standard) | 200 g |
2507011304_OMRON-ZN-PD03-SA_C7131670.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible