Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Ultrasonic timing IC MSKSEMI MSK1922 featuring analog comparators and first echo detection for anomaly detection factory
<
quality Ultrasonic timing IC MSKSEMI MSK1922 featuring analog comparators and first echo detection for anomaly detection factory
quality Ultrasonic timing IC MSKSEMI MSK1922 featuring analog comparators and first echo detection for anomaly detection factory
quality Ultrasonic timing IC MSKSEMI MSK1922 featuring analog comparators and first echo detection for anomaly detection factory
>
Specifications
Mfr. Part #:
MSK1922
Package:
QFN-32(5x5)
Key Attributes
Model Number: MSK1922
Product Description

Product Overview

The MSK1922 is a high-precision time measurement circuit that integrates analog comparators, analog switches, and Schmitt triggers, significantly simplifying peripheral circuitry. It features a first echo detection function for enhanced anti-interference capabilities. By reading the relative width of the first echo pulse, users can receive a signal strength indication, useful for identifying anomalies like abnormal ultrasonic transducers, increased wall coverings, or air bubbles in water. The device supports ultrasonic time-of-flight measurements (flow and reverse flow) and data reading via commands, reducing software operations and power consumption.

Product Attributes

  • Brand: Msksemi
  • Model: MSK1922
  • Copyright: Msksemi Incorporated
  • Website: www.msksemi.com

Technical Specifications

FeatureSpecificationDetails
Measurement RangeRange 1Single-channel single-precision mode: 90ps; Single-channel double-precision mode: 45ps
Range 23.5ns (0ns) to 2.4s; Minimum pulse interval, up to 4 pulses received
Range 3500ns to 4ms (at 4M high-speed clock)
PrecisionSingle-channel single-precision mode90ps
Double-precision mode45ps
Quadruple-precision mode22.5ps
Pulse ReceptionRange 2Can measure 3 pulses, automatically process 3 data points
First Wave DetectionCan measure the pulse width of the first wave
Temperature MeasurementSensors2 or 4 temperature sensors (PT500/PT1000 or higher)
FunctionalitySupports temperature measurement
Analog Input CircuitComponentsIntegrated analog switches for input selection, integrated Schmitt trigger
Power Consumption0.08A (when measuring every 30 seconds)
Application ScopeUltrasonic heat meters, water meters, Laser ranging
PackageQFN-32(5x5)
Ordering InformationMSK1922, QFN-32(5x5), 5000PCS
Pin DescriptionXIN/XOUTHigh-speed crystal oscillator input/output
VIOPort power supply
Control RegistersConfiguration Register 0Settings for fire port pulse count, clock division, calibration cycles, crystal startup time, temperature measurement ports, etc.
Configuration Register 1Settings for ALU calculation results, fast initialization, stop channel pulse count, start/fire pin function selection.
Configuration Register 2Interrupt trigger settings, edge sensitivity for channels, delay values for stop pulses.
Configuration Register 3Settings for auto-calculation of pulse measurements, first wave detection, overflow handling, measurement range 2 overflow time, relative delay for stop pulses.
Configuration Register 4Settings for delay of third stop pulse, pulse width measurement enable/disable, first wave detection edge sensitivity, comparator offset.
Read RegistersResult Registers (RES_0 to RES_3)Measurement results (fixed-point, 16-bit integer, 16-bit fractional). Negative values only in Measurement Range 1.
Status Register (STAT)Indicates temperature measurement short/open circuit, received pulse counts, coarse count overflow, TDC unit overflow, result address pointer.

2509051530_MSKSEMI-MSK1922_C50385426.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max