Product Overview
The MLX90824 is a highly integrated, PCB-less absolute pressure sensor designed for automotive applications. It measures pressure spans from 1 to 4 bar and features a digital SENT output. The sensor combines a MEMS pressure element, an interface IC, and passive components in a single package, offering excellent EMC performance and high accuracy due to its DSP-based signal interface. It supports flexible NTC thermistor input for linear temperature output and is factory calibrated and programmable for customized calibration curves. The device is qualified according to AEC-Q100 and AEC-Q103-002 standards and is developed as an ASIL B SEooC.
Product Attributes
- Brand: Melexis
- Certifications: AEC-Q100, AEC-Q103-002, ASIL B SEooC
- Output Protocol: SENT
- Package Type: PCB-less
- Pressure Measurement: Absolute
Technical Specifications
| Ordering Code | Pressure Range (bar) | Temperature Range (C) | Package | Option Code | Packing |
| MLX90824GXP-DAC-300-RE | 0.1 to 1.15 | -40 to 160 | SMP7 | 0.1 to 1.15bar absolute pressure / 193 to 3896LSB SENT output / NTC | Reel |
| MLX90824GXP-DAD-301-RE | 0.1 to 3 | -40 to 160 | SMP7 | 0.1 to 3bar absolute pressure / 193 to 3896LSB SENT output / NTC | Reel |
| MLX90824GXP-DAD-302-RE | 0.1 to 4 | -40 to 160 | SMP7 | 0.1 to 4bar absolute pressure / 193 to 3896LSB SENT output / NTC | Reel |
| Parameter | Symbol | Value | Units | Comment |
| Supply Voltage (overvoltage) | OV | 40 | V | Max 2 hours |
| Reverse Voltage Protection | RV | -40 | V | |
| Positive output voltage | 40 | V | ||
| Reverse output voltage | -40 | V | Max DC negative output at floating supply or supply shorted to output. Maximum DC negative output at operating supply: -5.5V. | |
| Max voltage on NTC pin | -0.2 to 2 | V | Max 1 minute at Ta = 25C | |
| Operating Ambient Temperature Range | TA | -40 to 160 | C | HTOL accelerated aging test equivalent to 3680 hours at 150C. |
| Extended Operating Ambient Temperature Range | -40 to 170 | C | 10 minutes continuous period, max 20 hours total duration over life | |
| Storage Temperature Range | -40 to 160 | C | ||
| Programming Ambient Temperature Range | -40 to 125 | C | ||
| Proof pressure (1 bar versions) | 5 | Bar | DAC-300 | |
| Proof pressure (>3 bar versions) | 10 | Bar | DAD-301 and DAD-302 | |
| Burst pressure (1 bar versions) | 6 | Bar | DAC-300 | |
| Burst pressure (>3 bar versions) | 16 | Bar | DAD-301 and DAD-302 | |
| ESD, human body model | 2000 | V | Class 1C acc. ANSI/ESDA/JEDEC JS-001 | |
| ESD, charged device model | 1000 | V | Class C3 acc. ANSI/ESDA/JEDEC JS-002 |