Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Versatile liquid level detection MICROCHIP LLC610D324-005 with Polysulfone or Trogamid housing materials factory
<
quality Versatile liquid level detection MICROCHIP LLC610D324-005 with Polysulfone or Trogamid housing materials factory
quality Versatile liquid level detection MICROCHIP LLC610D324-005 with Polysulfone or Trogamid housing materials factory
>
Specifications
Mfr. Part #:
LLC610D324-005
Key Attributes
Model Number: LLC610D324-005
Product Description

Product Overview

The Optomax Industrial Series liquid level switches offer versatile detection for a wide range of liquid types, including oil and water-based fluids. Designed for industrial environments, these switches feature robust construction with a choice of Polysulfone or Trogamid housing materials and multiple thread options for mounting. They provide direct load drive capability and operate with industrial supply voltages.

Product Attributes

  • Brand: SST Sensing Ltd.
  • Origin: UK
  • Housing Materials: Polysulfone (standard), Trogamid
  • Sensor Termination: 20AWG, 250mm PTFE wires, 8mm tinned

Technical Specifications

FeatureSpecification
Supply Voltage (Vs)4.5VDC to 15.4VDC or 8VDC to 30VDC
Supply Current (Is)2.5mA max. (Vs = 15.4VDC) or 7.5mA max. (Vs = 30VDC)
Output Sink/Source Current (lout)1A
Operating TemperaturesStandard: -25C to +80C; Extended: -40C to +125C
Storage TemperaturesStandard: -30C to +85C; Extended: -40C to +125C
Housing/Mounting OptionsM12x1x8g (with hex nut); 1/2 SAE (with O-ring); 1/4 NPT
Pressure Rating7 bar / 101 psi maximum (when correctly sealed)
Tightening Torque1.5 Nm / 13.26 in-lbs maximum
Output Voltage (lout = 1A, Vs = 4.515.4VDC)Output High: Vs - 1.5V max; Output Low: 0V + 0.5V max
Output Voltage (lout = 1A, Vs = 830VDC)Output High: Vs - 1.8V max; Output Low: 0V + 0.7V max

Notes:

  • Other sensor options available on request.
  • Hex nut and O-ring sold separately.
  • NPT version can be sealed with PTFE tape.
  • Above +85C, Trogamid is suitable for water-based liquids. Oil-based liquids may cause deformation and must be tested for compatibility.
  • Before use, check fluid compatibility with Polysulfone or Trogamid.
  • Minimum load impedance should not exceed Vs/max output current.
  • Shorting the output to Vs or 0V will result in irreparable damage.

Contact Information:

  • For other sensor options or technical assistance: technical@sstsensing.com
  • General Inquiries: sales@sstsensing.com
  • Tel: +44 (0)1236 459 020

2411261520_MICROCHIP-LLC610D324-005_C1526386.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max