Specifications
Absolute Accuracy:
15hpa
Pressure range:
-1bar~0pa
Response time:
1ms
Mfr. Part #:
MLX90809LXG-EAD-007-SP
Package:
SOIC-16
Key Attributes
Model Number: MLX90809LXG-EAD-007-SP
Product Description

MLX90809 Relative Pressure Sensor

The MLX90809 is a fully integrated relative pressure sensor designed for automotive and industrial applications. It features a high accuracy MEMS sensing element combined with a 16-bit microcontroller and analog front/back end circuitry. The sensor offers both ratiometric analog and digital SENT outputs, providing flexibility for various system integrations. Its robust, easy-to-seal package and factory calibration ensure reliability and ease of use in demanding environments, including a wide automotive temperature range and advanced diagnostic features.

Product Attributes

  • Brand: Melexis
  • Certifications: Automotive qualified
  • Material: MEMS, CMOS technology
  • Package: Robust, easy to seal

Technical Specifications

Part Number Pressure Range Output Type Temperature Range Accuracy
MLX90809LXG-EAD-000 0.05 to -1.05 bar 0.5 to 4.5 V analog -40C to 150C +/-1.5%FSO
MLX90809LXG-EAD-003 0 to 1 bar 0.5 to 4.5 V analog -40C to 150C +/-1.5%FSO
MLX90809LXG-EAD-007 0 to -1 bar 0.5 to 4.5 V analog -40C to 150C +/-1.5%FSO
MLX90809LXG-EAD-100 0.05 to -1.2 bar 193 to 3896 LSB SENT -40C to 150C +/-1.5%FSO

Absolute Maximum Ratings

Parameter Value Units Remarks
Supply Voltage (overvoltage) 18 V No time or temperature limit
Reverse Voltage Protection -14 V Max 1 hour at 150C; Max 24 hours at Room Temperature
Positive output voltage 18 V No time or temperature limit
Reverse output voltage -0.5 V No time or temperature limit
Operating Temperature Range -40 to 150 C
Storage Temperature Range -40 to 150 C
Burst pressure (Room Temperature) 5 Bar (AEC Q100 002)

General Electrical Specifications

Parameter Symbol Remarks Min Typ Max Units
Nominal supply voltage Vdd 4.5 5 5.5 V
Nominal supply current Idd No output load connected 7 8 mA
Analog Output Load (Resistive) Rload Pull up or Pull down 4.7 kOhm
Analog Output Load (Capacitive) Cload 2.2 470 nF
SENT Output Load (Capacitive) Cload 2.2 nF
SENT Output Load (C-R-C) CRCload 1.1nF + 220Ohm + 1.1nF
Diagnostic limits low Diag low Pull-up 4.7k, Pull-down 4.7k 3 %Vdd
Diagnostic limits high Diag high Pull-up 4.7k, Pull-down 8k 96 %Vdd
Clamp low Clamp low Programmable range with 8 bit resolution for the low clamping level, 9 for the high (for the default programmed levels see section 8), +/-10mV accuracy on the programmed clamping level 0 25 %Vdd
Clamp high Clamp high 50 100 %Vdd
Analog saturation output level high Vsat high Pull-up 4.7k, Pull-down 4.7k, Pull-down 10k 97 100 %Vdd
Analog saturation output level low Vsat low Pull-up 4.7k, Pull-down 4.7k 0 3 %Vdd
Power up time Time from reaching minimum allowed supply voltage of 4.5V till having the output within specification 5.5 msec