Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Industrial current transducer LEM LT58-S7SP8 offering galvanic isolation and wide frequency bandwidth factory
<
quality Industrial current transducer LEM LT58-S7SP8 offering galvanic isolation and wide frequency bandwidth factory
>
Specifications
Mfr. Part #:
LT58-S7/SP8
Key Attributes
Model Number: LT58-S7/SP8
Product Description

Product Overview

The LT 58-S7/SP8 is a closed-loop (compensated) current transducer utilizing Hall effect technology for precise electronic measurement of DC, AC, and pulsed currents. It provides galvanic isolation between the primary and secondary circuits, offering excellent accuracy, linearity, low temperature drift, and a wide frequency bandwidth. This transducer is suitable for industrial applications, including AC and DC motor drives, UPS, SMPS, and welding power supplies.

Product Attributes

  • Brand: LEM
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1
  • Material: Isolated plastic case
  • Origin: Not specified
  • Color: Not specified

Technical Specifications

ParameterValueUnitConditions
Product NameLT 58-S7/SP8
Primary Nominal Current (IPN)50A rms
Primary Current Measuring Range (IPM)0 .. 70A
Secondary Nominal Current (ISN)50mA rms
Conversion Ratio (KN)1 : 1000
Supply Voltage (VC) 12 .. 15V ( 5 %)
Current Consumption (IC)20 + ISmA@ 15 V
Overall Accuracy (XG) 0.8%@ IPN, TA = 25C
Linearity Error (L)< 0.2%Typ
Electrical Offset Current (IOE) 0.10mA@ IP = 0, TA = 25C
Magnetic Offset Current (IOM) 0.20mA@ IP = 0, specified RM, after 3 x IPN overload
Temperature Variation of IO (IOT) 0.35 / 0.64mA- 25C .. + 70C
Reaction Time to 10% of IPN step< 500ns
Response Time to 90% of IPN step< 1sWith a di/dt of 100 A/s, IPN = 50 A
di/dt Accurately Followed> 100A/s
Frequency Bandwidth (- 3 dB) (BW)DC .. 100kHz
Ambient Operating Temperature (TA)- 25 .. + 70C
Ambient Storage Temperature (TS)- 40 .. + 85C
Secondary Coil Resistance (RS)11@ TA = 70C
Mass68g
Rms Voltage for AC Insulation Test (Vd)3.52kV50 Hz, 1 min, between primary and secondary
Impulse Withstand Voltage (Vw)6.5kV1.2/50 s, between primary and secondary
Creepage Distance (dCp)10mmOn housing, OV 3, PD2
Clearance (dCI)6mmOn housing, OV 3, PD2
Comparative Tracking Index (CTI)275Group IIIa
Rated Insulation Voltage (Basic)600VEN 50178 / IEC 61010-1
Rated Insulation Voltage (Reinforced)300VEN 50178 / IEC 61010-1
Primary Through-hole Diameter20mm
Fastening2 holes 5.4 mm (M5 screws, 1.5 Nm) or 2 notches 4.2 mm (M4 screws, 0.75 Nm)General tolerance 0.5 mm