Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Ambient light sensor LITEON LTR-308ALS-01 with programmable interrupt hysteresis and CMOS technology factory
<
quality Ambient light sensor LITEON LTR-308ALS-01 with programmable interrupt hysteresis and CMOS technology factory
>
Specifications
Operating Temperature:
-40℃~+85℃
Interface:
I2C
Measurement Type:
Light Intensity
Voltage - Supply:
1.7V~3.6V
Photoperceptivity:
157klx
Mfr. Part #:
LTR-308ALS-01
Package:
SMD
Key Attributes
Model Number: LTR-308ALS-01
Product Description

Product Overview

The LTR-308ALS-01 is an integrated, low-voltage I2C ambient light sensor (ALS) housed in a miniature 2x2mm chipled surface mount package. It offers a linear response across a wide dynamic range, suitable for both low and bright ambient light conditions. The sensor features a programmable interrupt with hysteresis, eliminating the need for constant polling and improving system efficiency. Its CMOS design and factory-set trimming ensure minimal variations between sensors, simplifying manufacturing. This sensor is designed to control display panel brightness in mobile, computing, and consumer devices.

Product Attributes

  • Brand: LITE-ON
  • Origin: Taiwan, R.O.C.
  • Certifications: RoHS and Halogen free compliant

Technical Specifications

ParameterSymbolMin.Typ.Max.UnitCondition
Supply VoltageVDD1.73.6V
Interface signal input highVI2Chigh1.5VDDV
Interface signal input lowVI2Clow00.4V
Operating TemperatureTope-4085C
Active Supply Current110uAMax. duty cycle, Vdd=1.8V, Gain 3x
Standby Current1uA
Shutdown Mode Wakeup Time from Standbyt510msFrom Standby to Active mode
ALS Resolution1620BitProgrammable for 16, 17, 18, 19, 20 Bit
ALS Lux accuracy-1010%White LED, 5000K, Ta = 25
Dark Level Count05Count0 Lux, 18-bit resolution
Integration time50400msWith 50/60Hz Rejection
50/60 Hz flicker noise error-5+5%
SCL clock frequencySCL f1400kHz
Bus free time between a STOP and START conditiont BUF1.3us
Hold time (repeated) START condition. After this period, the first clock pulse is generatedt STA HD0.6us
LOW period of the SCL clockt LOW1.3us
HIGH period of the SCL clockt HIGH0.6us
Set-up time for a repeated START conditiont STA SU0.6us
Set-up time for STOP conditiont STO SU0.6us
Rise time of both SDA and SCL signalsrt30300ns
Fall time of both SDA and SCL signalsft30300ns
Data hold timet DAT HD0.30.9us
Data setup timet DAT SU100ns
Pulse width of spikes which must be suppressed by the input filtert SP050ns
I2C Slave Address (Default)0x53

2410121549_LITEON-LTR-308ALS-01_C492382.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max