quality current measurement device LEM LA125-P with low temperature drift and excellent linearity performance factory
<
quality current measurement device LEM LA125-P with low temperature drift and excellent linearity performance factory
>
Specifications
working temperature:
-40℃~+85℃
Current Range:
±300A
Voltage - Supply:
-15V~-12V;12V~15V
Band Width:
100kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
LA125-P
Package:
Through Hole
Key Attributes
Model Number: LA125-P
Product Description

Product Overview

The LEM LA 125-P/SP4 is a closed-loop Hall effect current transducer designed for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits. It offers excellent accuracy, linearity, low temperature drift, and a wide frequency bandwidth, making it suitable for demanding applications in AC variable speed drives, servo motor drives, static converters, UPS, SMPS, and welding power supplies, particularly in the traction domain.

Product Attributes

  • Brand: LEM
  • Certifications: UL 94-V0, EN 50155:1995
  • Material: Insulating plastic case

Technical Specifications

SpecificationValueNotes
Primary Nominal Current (IPN)125 A (rms)
Primary Current Measuring Range (IPM)0 .. 300 A
Secondary Nominal Current (ISN)62.5 mA (rms)
Conversion Ratio (KN)1 : 2000
Supply Voltage (UC) 12 .. 15 V ( 5 %)
Current Consumption (IC)16 mA (@ 15 V) + IS
Accuracy @ IPN, TA = 25 C 0.60 % (@ 15 V) / 0.80 % (@ 12 .. 15 V)
Linearity Error (L)< 0.15 %Typ
Offset Current (IO) @ IP = 0, TA = 25 C 0.20 mA
Magnetic Offset Current (IOM) 0.25 mAAfter 3 x IPN overload
Temperature Variation of IO 0.20 .. 0.50 mA (-25C to +85C) / 0.30 .. 0.80 mA (-40C to -25C)
Reaction Time (tra)< 500 ns
Step Response Time (tr) to 90%< 1 s
di/dt Accurately Followed> 200 A/s
Frequency Bandwidth (BW) (-1 dB)DC .. 100 kHz
Ambient Operating Temperature (TA)- 40 .. + 85 C
Ambient Storage Temperature (TS)- 45 .. + 100 C
Secondary Coil Resistance (RS)76 (@ TA = 70 C) / 80 (@ TA = 85 C)
Mass55 g
Isolation Test Voltage (Ud)4.5 kV rms / 8.4 kV (1) rms50 Hz, 1 min
Creepage Distance (dCp)8.8 mm
Clearance (dCI)8.8 mm
Comparative Tracking Index (CTI)175Group IIIa
Primary Through-hole17 4.5 mm or 13 11 mm
Secondary Connection4 pins 0.63 x 0.56 mmRecommended PCB hole 0.9 mm
Supplementary Fastening2 holes 1.75 mmRecommended PCB hole 2.4 mm