Specifications
working temperature:
-10℃~+80℃
Current Range:
±900A
Voltage - Supply:
±15V
Band Width:
50kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
HAS400-S
Package:
Through Hole
Key Attributes
Model Number: HAS400-S
Product Description

LEM HAS 50..600-S Current Transducer

The LEM HAS 50..600-S is a current transducer designed for electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits. It features a Hall effect measuring principle and an insulating plastic case. Key advantages include easy mounting, low power consumption, small size, a single design for a wide current range, and high immunity to external interference, making it suitable for industrial applications such as AC variable speed drives, UPS, and SMPS.

Product Attributes

  • Brand: LEM
  • Material: Insulating plastic case made of polycarbonate PBT recognized according to UL 94-V0
  • Certifications: UL 94-V0, EN 50178, UL 508, EN 50178: 1997, UL 508: 2010
  • Application Domain: Industrial

Technical Specifications

TypePrimary nominal rms current measuring range IPN (A)Primary current IPM (A)Supply voltage (5 %) UCCurrent consumption ICInsulation resistance @ 500 V DCOutput voltage (Analog) @ IPN, RL = 10 k, TA = 25 COutput internal resistance RoutLoad resistance RL 2)Accuracy @ IPN, TA = 25 C (excluding offset)Linearity error L (0 .. IPN)Electrical offset voltage VOE, TA = 25 CHysteresis offset voltage VOH @ IP = 0, after an excursion of 1 IPNTemperature coefficient of VOETemperature coefficient of Vout (% of reading)Step response time to 90 % of IPNdi/dt accurately followedFrequency bandwidth (-3 dB) 4)Ambient operating temperature TAAmbient storage temperature TSMassUd Rms voltage for AC insulation test, 50 Hz/1 minW Impulse withstand voltage 1.2/50 sMin dCp Creepage distancedCI ClearanceCTI Comparative tracking index (group IIIa)
HAS 50-S5015015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<2 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 100-S10030015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 200-S20060015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 300-S30090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 400-S40090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 500-S50090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 600-S60090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275