Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Compact Current Transducer LEM HXS 20-NP with High Immunity to External Interference and Consumption factory
<
quality Compact Current Transducer LEM HXS 20-NP with High Immunity to External Interference and Consumption factory
>
Specifications
working temperature:
-40℃~+105℃
Current Range:
5A;10A;20A
Voltage - Supply:
5V
Current Terminal Resistance:
0.05mΩ
Band Width:
50kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
HXS 20-NP
Package:
Through Hole,18.7x16.7mm
Key Attributes
Model Number: HXS 20-NP
Product Description

Product Description

The LEM HXS 20-NP is a current transducer designed for the electronic measurement of DC, AC, and pulsed currents. It provides galvanic separation between the primary and secondary circuits, utilizing the Hall effect measuring principle. This multirange transducer is ideal for applications requiring a small size, space-saving design, high immunity to external interference, and a single power supply. Its applications include AC variable speed drives, servo motor drives, static converters for DC motor drives, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), and power supplies for welding applications. The transducer is recognized according to UL 94-V0 and offers fixed offset and sensitivity with low power consumption.

Product Attributes

  • Brand: LEM
  • Model: HXS 20-NP
  • Origin: Switzerland (implied by LEM International SA address)
  • Material: Insulating plastic case recognized according to UL 94-V0
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1, UL 508

Technical Specifications

ParameterValueUnitNotes
Primary nominal RMS current (IP N)20AFor HXS 20-NP
Primary current, measuring range (IP M)±60A
Nominal sensitivity (SN)0.625V/A
Output voltage (Analog) (Uout)±(0.625·IP/ IP N)V@ IP UO E
Reference voltage (Uref)2.5 ±0.025V1)
Output impedance (typ.)200Ω
Load resistance (RL)2
Output internal resistance (Rout)< 5Ω
Load capacitance (CL) (±20 %)4.7nF
Supply voltage (UC) (±5 %)5V2)
Current consumption @ UC = 5 V19mA
Error (@ IP N, TA = 25 °C)±1%3)
Linearity error (0 ... IP N)±0.5%
Linearity error (0 ... 3 × IP N)±1%
Temperature coefficient of UO E (+25 ... 105 °C)±0.4mV/K
Temperature coefficient of UO E (−40 ... +25 °C)±0.525mV/K
Temperature coefficient of Uref (+25 ... 105 °C)±0.01%/K
Temperature coefficient of Uref (−40 ... +25 °C)±0.015%/K
Temperature coefficient of UO E /Uref±0.15mV/K
Temperature coefficient of S±0.05% of reading/KTCS
Electrical offset voltage (@ IP = 0, TA = 25 °C)±0.0125VUO E
Magnetic offset voltage (@ IP = 0 after overload)±0.7%3 × IPN
Delay time to 10 % (tD 10)< 3µsfor IP N step
Delay time to 90 % (tD 90)< 5µsfor IP N step 4)
Output voltage noise (DC ... 10 kHz)< 20mVppUno
Output voltage noise (DC ... 1 MHz)< 40mVppUno
Frequency bandwidth (−3 dB)DC ... 50kHz5)
Ambient operating temperature (TA)−40 ... +105°C1) UL recognized until +85 °C
Ambient storage temperature (TA st)−40 ... +105°C
Mass (m)10g
Insulation test voltage (Ud RMS)3.5kV50 Hz, 1 min
Creepage distance (dCp)7.48mm
Clearance (dCI)6.6mm
Comparative tracking index (CTI)> 600(group I)
Rated insulation voltage (Basic)600VAccording to EN 50178 / IEC 61010-1
Rated insulation voltage (Reinforced)300 / 150VAccording to EN 50178 / IEC 61010-1
Primary RMS current (nominal IP N)5, 10, 20AFor different PCB layouts
Primary RMS current (maximum IP)15, 30, 60AFor different PCB layouts
Primary resistance RP0.05, 0.2, 1For different PCB layouts
Primary insertion inductance LP0.025, 0.1, 0.4µHFor different PCB layouts

2411261447_LEM-HXS-20-NP_C6061228.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible