Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Industrial hall effect current sensor LEM has200-s sp50 designed for accurate dc ac current sensing factory
<
quality Industrial hall effect current sensor LEM has200-s sp50 designed for accurate dc ac current sensing factory
>
Specifications
working temperature:
-10℃~+80℃
Current Range:
±600A
Voltage - Supply:
±15V
Band Width:
50kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
Has200-s/sp50
Package:
Through Hole
Key Attributes
Model Number: has200-s/sp50
Product Description

Product Overview

The LEM HAS 50..600-S/SP50 is a Hall effect current sensor designed for measuring DC, AC, and pulsed currents. It features electrical isolation between primary and secondary circuits, a wide measurement range, and a compact, easy-to-mount design. This sensor is suitable for various industrial applications including AC variable speed drives, DC motor traction, battery power, UPS, SMPS, and welding power supplies.

Product Attributes

  • Brand: LEM
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1
  • Insulation Housing Material: Compliant with UL 94-V0

Technical Specifications

ModelPrimary Rated Current (IPN) (A)Primary Current Measurement Range (IPM) (A)RoHS Batch NumberPower Supply Voltage (VC) ( 5 %)Current Consumption (IC)Isolation Resistance @ 500 VDCOutput Voltage (VOUT) @ IPN, RL =10 k, TA = 25COutput Internal Resistance (ROUT)Load Resistance (RL)Accuracy @ IPN , TA = 25C (excluding offset)Linearity Error (L) (0 .. IPN)Voltage Offset (VOE), TA = 25CHysteresis Offset Voltage (VOH)TCVOE (HAS 50-S/SP50)TCVOE (HAS 100..600-S/SP50)TCVOUT (% of reading)Response Time (tr)di/dt Following AccuracyBandwidth (- 3 dB)Operating Temperature (TA)Storage Temperature (TS)Mass (m)AC Isolation Test Voltage (Vd) @ 50 Hz, 1 minImpulse Withstand Voltage (Vw) 1.2/50 sMin. Creepage Distance (dCp)Min. Clearance Distance (dCI)Comparative Tracking Index (CTI)
HAS 50-S/SP5050 15076348 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mV< 2 mV/KN/A< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275
HAS 100-S/SP50100 30076348 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mVN/A< 1 mV/K< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275
HAS 200-S/SP50200 60076348 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mVN/A< 1 mV/K< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275
HAS 300-S/SP50300 90076349 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mVN/A< 1 mV/K< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275
HAS 400-S/SP50400 90076349 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mVN/A< 1 mV/K< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275
HAS 500-S/SP50500 90076349 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mVN/A< 1 mV/K< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275
HAS 600-S/SP50600 90076349 15 V 15 mA> 1000 M 4V~ 100 > 1 k< 1 %< 1 % of IPN< 20 mV< 20 mVN/A< 1 mV/K< 0.1 %/K< 3 s> 50 A/sDC .. 50 kHz- 10 .. + 80 C- 25 .. + 80 C~ 60 g3.6 kV> 6.6 kV7.08 mm6.23 mm275

2304140030_LEM-has200-s-sp50_C444898.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max