Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Industrial current transducer LEM HAS500-P for DC AC pulsed current measurement featuring galvanic isolation factory
<
quality Industrial current transducer LEM HAS500-P for DC AC pulsed current measurement featuring galvanic isolation factory
>
Specifications
Mfr. Part #:
HAS500-P
Package:
Through Hole
Key Attributes
Model Number: HAS500-P
Product Description

Product Overview

The LEM HAS 50...600-P is a current transducer designed for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between the primary and secondary circuits. It features an insulating plastic case made of UL 94-V0 recognized polycarbonate PBT, offering easy mounting, low power consumption, and a small, space-saving design. This transducer is ideal for applications requiring high immunity to external interference and a wide current rating range from a single design. It is suitable for industrial applications including AC variable speed drives, static converters for DC motor drives, battery-supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), and power supplies for welding applications.

Product Attributes

  • Brand: LEM
  • Material: Insulating plastic case made of polycarbonate PBT (UL 94-V0 recognized)
  • Certifications: EN 50178:1997, UL 508: 2010
  • Application Domain: Industrial

Technical Specifications

TypePrimary nominal rms current IP N (A)Primary current measuring range IP M (A)RoHS since date codeUC Supply voltage (5 %)IC Current consumptionRINS Insulation resistance @ 500 V DCVout Output voltage (Analog) @ IP N, RL = 10 k, TA = 25 CRout Output internal resistanceRL Load resistanceAccuracy @ IP N, TA = 25 C (excluding offset)L Linearity error (0 ... IP N)VO E Electrical offset voltage, TA = 25 CVO H Hysteresis offset voltage @ IP = 0, after an excursion of 1 IP NTCVO E Temperature coefficient of VO ETCVout Temperature coefficient of Vout (% of reading)tr Step response time to 90 % of IP NBW Frequency bandwidth (small signal, 3 dB)TA Ambient operating temperatureTS Ambient storage temperaturem Mass
HAS 50-P501504606515 V15 mA> 1000 M4 Vapprox 100 > 1 k< 1 % of IP N< 1 % of IP N< 20 mV< 20 mV< 2 mV/K< 0.1 %/K< 3 sDC ... 50 kHz10 ... +80 C25 ... +85 C80 g
HAS 100-P10030046062< 1 % of IP N< 1 % of IP N< 20 mV< 20 mV< 1 mV/K
HAS 200-P20060076273
HAS 300-P30090076273
HAS 400-P40090046131
HAS 500-P50090046216
HAS 600-P60090076273

Insulation Coordination

Ud RMS voltage for AC insulation test, 50 Hz/1 minW Impulse withstand voltage 1.2/50 sMin dCp Creepage distancedCI ClearanceCTI Comparative tracking index (group IIIa)
3.6 kV> 6.6 kV7 mm4.6 mm275

Application Examples (According to EN 50178 and IEC 61010-1)

  • Over voltage category OV 3
  • Pollution degree PD2
  • Non-uniform field

Safety Notes

  • This transducer must be used in limited-energy secondary circuits according to IEC 61010-1.
  • This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturers operating instructions.
  • Caution, risk of electrical shock: When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage.
  • This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used.
  • Main supply must be able to be disconnected.

Rated Insulation Voltage

Nominal voltageBasic insulationReinforced insulation
EN 50178300 V300 V150 V
IEC 61010-1300 V300 V150 V

Dimensions

(Diagram not included in text, dimensions in mm)

Mechanical Characteristics

  • General tolerance 0.5 mm
  • Transducer fastening: 1 hole 4.5 mm, 1 M4 steel screw
  • Recommended fastening torque: 0.75 Nm (10 %)
  • Connection of secondary: JST MB4P-90H

Remarks

  • Vout is positive when IP flows in the direction of the arrow.
  • Temperature of the primary conductor should not exceed 100 C.
  • Installation of the transducer must be done according to LEM Transducer Generic Mounting Rules (Document NANE120504).
  • Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole.
  • For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact LEM.

2411271955_LEM-HAS500-P_C454789.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible