Product Overview
The LEM HAS 50...600-P is a current transducer designed for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between the primary and secondary circuits. It features an insulating plastic case made of UL 94-V0 recognized polycarbonate PBT, offering easy mounting, low power consumption, and a small, space-saving design. This transducer is ideal for applications requiring high immunity to external interference and a wide current rating range from a single design. It is suitable for industrial applications including AC variable speed drives, static converters for DC motor drives, battery-supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), and power supplies for welding applications.
Product Attributes
- Brand: LEM
- Material: Insulating plastic case made of polycarbonate PBT (UL 94-V0 recognized)
- Certifications: EN 50178:1997, UL 508: 2010
- Application Domain: Industrial
Technical Specifications
| Type | Primary nominal rms current IP N (A) | Primary current measuring range IP M (A) | RoHS since date code | UC Supply voltage (5 %) | IC Current consumption | RINS Insulation resistance @ 500 V DC | Vout Output voltage (Analog) @ IP N, RL = 10 k, TA = 25 C | Rout Output internal resistance | RL Load resistance | Accuracy @ IP N, TA = 25 C (excluding offset) | L Linearity error (0 ... IP N) | VO E Electrical offset voltage, TA = 25 C | VO H Hysteresis offset voltage @ IP = 0, after an excursion of 1 IP N | TCVO E Temperature coefficient of VO E | TCVout Temperature coefficient of Vout (% of reading) | tr Step response time to 90 % of IP N | BW Frequency bandwidth (small signal, 3 dB) | TA Ambient operating temperature | TS Ambient storage temperature | m Mass |
| HAS 50-P | 50 | 150 | 46065 | 15 V | 15 mA | > 1000 M | 4 V | approx 100 | > 1 k | < 1 % of IP N | < 1 % of IP N | < 20 mV | < 20 mV | < 2 mV/K | < 0.1 %/K | < 3 s | DC ... 50 kHz | 10 ... +80 C | 25 ... +85 C | 80 g |
| HAS 100-P | 100 | 300 | 46062 | < 1 % of IP N | < 1 % of IP N | < 20 mV | < 20 mV | < 1 mV/K | ||||||||||||
| HAS 200-P | 200 | 600 | 76273 | |||||||||||||||||
| HAS 300-P | 300 | 900 | 76273 | |||||||||||||||||
| HAS 400-P | 400 | 900 | 46131 | |||||||||||||||||
| HAS 500-P | 500 | 900 | 46216 | |||||||||||||||||
| HAS 600-P | 600 | 900 | 76273 |
Insulation Coordination
| Ud RMS voltage for AC insulation test, 50 Hz/1 min | W Impulse withstand voltage 1.2/50 s | Min dCp Creepage distance | dCI Clearance | CTI Comparative tracking index (group IIIa) | |
| 3.6 kV | > 6.6 kV | 7 mm | 4.6 mm | 275 |
Application Examples (According to EN 50178 and IEC 61010-1)
- Over voltage category OV 3
- Pollution degree PD2
- Non-uniform field
Safety Notes
- This transducer must be used in limited-energy secondary circuits according to IEC 61010-1.
- This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the manufacturers operating instructions.
- Caution, risk of electrical shock: When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage.
- This transducer is a build-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used.
- Main supply must be able to be disconnected.
Rated Insulation Voltage
| Nominal voltage | Basic insulation | Reinforced insulation | |
| EN 50178 | 300 V | 300 V | 150 V |
| IEC 61010-1 | 300 V | 300 V | 150 V |
Dimensions
(Diagram not included in text, dimensions in mm)
Mechanical Characteristics
- General tolerance 0.5 mm
- Transducer fastening: 1 hole 4.5 mm, 1 M4 steel screw
- Recommended fastening torque: 0.75 Nm (10 %)
- Connection of secondary: JST MB4P-90H
Remarks
- Vout is positive when IP flows in the direction of the arrow.
- Temperature of the primary conductor should not exceed 100 C.
- Installation of the transducer must be done according to LEM Transducer Generic Mounting Rules (Document NANE120504).
- Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole.
- For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact LEM.
2411271955_LEM-HAS500-P_C454789.pdf