Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Closed loop Hall effect current transducer LEM LT508-S6 for accurate DC AC and pulsed current measurement factory
<
quality Closed loop Hall effect current transducer LEM LT508-S6 for accurate DC AC and pulsed current measurement factory
>
Specifications
working temperature:
-10℃~+70℃
Current Range:
±800A
Voltage - Supply:
-18V~-15V;15V~18V
Band Width:
100kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
LT508-S6
Key Attributes
Model Number: LT508-S6
Product Description

Product Overview

The LEM LT 508-S6 is a closed-loop Hall effect current transducer designed for the electronic measurement of DC, AC, and pulsed currents. It provides galvanic separation between the primary and secondary circuits, offering excellent accuracy, very good linearity, low temperature drift, and optimized response time. This transducer is ideal for applications requiring high immunity to external interference and current overload capability, such as AC variable speed drives, static converters, UPS, and SMPS.

Product Attributes

  • Brand: LEM
  • Model: LT 508-S6
  • Certifications: UL 94-V0 (insulating plastic case), EN 50178, UL 508
  • Application Domain: Industrial

Technical Specifications

ParameterValueUnitNotes
Primary Nominal RMS Current (IPN)500A
Primary Current Measuring Range (IPM)0 800A
Measuring Resistance (RM)0 - 40 (at 15 V @ 500 A) / 0 - 5 (at 18 V @ 800 A) / 0 - 60 (at 15 V @ 500 A) / 0 - 15 (at 18 V @ 800 A)min/max values
Secondary Nominal RMS Current (ISN)100mA
Conversion Ratio (KN)1 : 5000
Supply Voltage (UC)15 18V(5 %)
Current Consumption (IC)20 (+ IS)mA(@ 15 V)
Overall Accuracy (@ IPN, TA = 25 C)0.4%
Linearity Error (L)< 0.1%Typ
Electrical Offset Current (IOE) (@ IP = 0, TA = 25 C)0.13mA
Magnetic Offset Current (IOM) (@ IP = 0 and specified RM, after overload)0.14mA1)
Temperature Variation of IO (TA = -10 C +70 C)0.15 / 0.64mA
Reaction Time< 500ns
Step of Response Time (tr) (to 90 % of IPN)< 1s2)
di/dt Accurately Followed> 100A/s
Frequency Bandwidth (BW) (3 dB)DC 100kHz
Ambient Operating Temperature (TA)10 +70C
Ambient Storage Temperature (TS)25 +80C
Resistance of Secondary Winding (RS) (@ TA = 70 C)60
Mass320g
Impulse Withstand Voltage (W) (1.2/50 s)9.1kV
Creepage Distance (dCp) (On housing)25.8mm2)
Clearance (dCI) (On housing)11.5mm2)
Comparative Tracking Index (CTI) (group IIIa)275
Rated Insulation Voltage (Basic)600VEN 50178 / IEC 61010-1
Rated Insulation Voltage (Reinforced)300VEN 50178 / IEC 61010-1
Primary Through-hole Diameter35mm

2410121916_LEM-LT508-S6_C454801.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max