Specifications
working temperature:
-40℃~+85℃
Current Range:
16.7A;25A;33.3A;50A;100A
Voltage - Supply:
-11.4V~15.75V
Response Time (tr):
100ns
Sensitivity:
0.5mA/A
Bidirectional Current Detection:
Support
Mfr. Part #:
LAX 100-NP
Key Attributes
Model Number: LAX 100-NP
Product Description

Product Overview

The LEM LAX SERIES is a closed-loop (compensated) current transducer utilizing Hall effect technology for the electronic measurement of DC, AC, and pulsed currents. It provides galvanic isolation between the primary and secondary circuits, featuring a low-profile design for simplified integration with power modules. The transducer offers multirange capability with a single device and is suitable for industrial applications.

Product Attributes

  • Brand: LEM
  • Certifications: UL508 - UR marking, EN 50178, IEC 61010-1
  • Application Domain: Industrial
  • Material: Isolated plastic case recognized according to UL 94-V0

Technical Specifications

ParameterSymbolUnitMiniTypMaxiConditions
General Data
Primary nominal current rmsIPNA16-100At 100 Apply derating according to fig. 2 and 3
Primary current, measuring rangeIPMA--±160* VC = ± 15 V ± 5%
Secondary nominal current rmsISNmA-50 at 100-At 100
Supply voltageVCV±11.4±15±15.75-
Current consumptionICmA-10 + IS12 + IS-
Primary turnsNP-1-3-
Measuring resistanceRMΩ-50-Unless otherwise noted
Accuracy Data (at TA = 25°C, VC = ± 15 V, RM = 50 Ω, NP = 1 turn, high speed PCB design, unless otherwise noted)
Electrical offset currentIOEµA-1500150VC = full range
Electrical offset currentIOEµA-330-330- 25°C .. + 85°C, VC = full range
Electrical offset currentIOEµA-500-500* - 40°C .. + 85°C, VC = full range
SensitivityGmA/A-0.5--
Sensitivity errorεG%-0.4700.47± 100 A range
Sensitivity errorεG%0.10.28-± 50 A range
Sensitivity errorεG%0.110.32-± 100 A range, low speed 1 turn PCB design
Overall accuracyXG%-0.91-0.91= IOE + εG + εL
Reaction time to 90%trµs-0.17-dIP/dt = 100 A/µs, high and low speed PCB designs
Frequency bandwidth (typical)BWkHz-> 300-IP = 25 A, -1 dB, 1 turn
Frequency bandwidth (typical)BWkHz-> 300-IP = 12.5 A, -1 dB, 2 turns
Frequency bandwidth (typical)BWkHz-> 300-IP = 8.3 A, -1 dB, 3 turns
Absolute Maximum Ratings
Primary AC current rms (3 primary jumpers in parallel)IPNA--70up to 2 kHz (See figure 3)
Primary continuous direct current (3 primary jumpers in parallel)IPN DCA--100up to TA = 50°C. Linear derating to 50 A at 85°C. (See figure 2)
Maximum supply voltageVCV--± 20(not operating)
Maximum busbar temperature (jumper)-°C--100-
Ambient operating temperatureTA°C-40-85-
Ambient storage temperatureTS°C-40-90-
Isolation Characteristics
Rms voltage for AC isolation test, 50 Hz, 1 min, between primary and secondaryVdkV-3.5--
Impulse withstand voltage 1.2/50 µsVwkV-8--
Partial discharge extinction voltage rms @ 10pCVekV> 1.3---
Creepage distancedCpmm-8--
Clearance distancedCImm-8--
Comparative Tracking IndexCTIV-600--