Open loop multi-range current transducer for electronic measurement of DC, AC, pulsed currents with galvanic separation between primary and secondary circuits. Features include voltage output, single +5 V supply, low power consumption, compact design for PCB mounting, factory calibration, and high bandwidth with a very low loss magnetic core. Advantages include an extremely low profile (h=12 mm), low footprint, low offset drift, and over-drivable Uref. Applications span AC variable speed and servo motor drives, static converters for DC motor drives, battery supplied applications, UPS, SMPS, welding power supplies, combiner boxes, and MPPT.
Product Attributes
- Brand: LEM International SA
- Certifications: EN 50178, IEC 61010-1, IEC 61326-1, UL 508, CSA C22.2 NO. 14-10
- Application Domain: Industrial
Technical Specifications
| Model | Primary Nominal RMS Current (IP N) | Primary Current Measuring Range (IP M) | Supply Voltage (UC) | Output Voltage Range (Uout - Uref) | Frequency Bandwidth (-3 dB) (BW) | Delay Time @ 10% (tD 10) | Delay Time @ 90% (tD 90) | Electrical Offset Voltage (UO E) | Temperature Coefficient of UO E | Sensitivity Error (S) | Temperature Coefficient of S (TCS) |
| HLSR 10-P | 10 A | -25 ... 25 A | 4.5 ... 5.5 V | -2 ... 2 V | 400 kHz | 2 s | 2.5 s | -5 ... 5 mV | -0.075 ... 0.075 mV/K | -0.5 ... 0.5 % | -200 ... 200 ppm/K |
| HLSR 16-P | 16 A | -40 ... 40 A | 4.5 ... 5.5 V | -2 ... 2 V | 400 kHz | 2 s | 2.5 s | -5 ... 5 mV | -0.075 ... 0.075 mV/K | -0.5 ... 0.5 % | -200 ... 200 ppm/K |
| HLSR 20-P | 20 A | -50 ... 50 A | 4.5 ... 5.5 V | -2 ... 2 V | 400 kHz | 2 s | 2.5 s | -5 ... 5 mV | -0.075 ... 0.075 mV/K | -0.5 ... 0.5 % | -200 ... 200 ppm/K |