quality Industrial Current Transducer LEM LXS 15-NPS with LTS Footprint Compatibility and Galvanic Isolation factory
>
Specifications
working temperature:
-40℃~+105℃
Current Range:
15A
Voltage - Supply:
4.75V~5.25V
Sensitivity:
41.67mV/A
Mfr. Part #:
LXS 15-NPS
Key Attributes
Model Number: LXS 15-NPS
Product Description

LXS Series Current Transducer

The LXS series are closed-loop multi-range current transducers with voltage output, designed for the electronic measurement of DC, AC, and pulsed currents. They provide galvanic separation between the primary and secondary circuits. Key advantages include very low offset drift, high dv/dt immunity, LTS footprint compatibility, and an extended measuring range for unipolar measurement. These transducers are ideal for applications such as AC variable speed and servo motor drives, static converters for DC motor drives, battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), power supplies for welding applications, and solar inverters. They are suitable for industrial application domains.

Product Attributes

  • Brand: LEM
  • Certifications: UL 508, CSA C22.2 NO. 14-10, IEC 61800 series, IEC 62109-1, IEC 62477-1
  • Application Domain: Industrial

Technical Specifications

Parameter Symbol Unit LXS 6-NPS (Min) LXS 6-NPS (Typ) LXS 6-NPS (Max) LXS 15-NPS (Min) LXS 15-NPS (Typ) LXS 15-NPS (Max) LXS 25-NPS (Min) LXS 25-NPS (Typ) LXS 25-NPS (Max) Comment
Primary nominal RMS current IP N A - 6 - - 15 - - 25 - Apply derating according to fig. 16, 17, 18
Primary current, measuring range IP M A -20 - 20 -51 - 51 -85 - 85
Supply voltage UC V 4.75 5 5.25 4.75 5 5.25 4.75 5 5.25
Output voltage @ IP = 0 A Vout V - 2.5 - - 2.5 - - 2.5 -
Electrical offset voltage VO E mV -15 - 15 -13 - 13 -11 - 11 100 % tested
Temperature coefficient of Vout @ IP = 0 A TCVout ppm/K - 70 - - 80 - - 80 - ppm/K of 2.5 V, -40 C ... 105 C
Theoretical sensitivity Gth mV/A - 104.2 - - 41.67 - - 25 - 625 mV/ IP N
Sensitivity error G % -0.2 - 0.2 -0.2 - 0.2 -0.2 - 0.2 100 % tested
Temperature coefficient of G TCG ppm/K - 45 - - 45 - - 45 - -40 C ... 105 C
Linearity error L % of IP N -0.1 - 0.1 -0.1 - 0.1 -0.1 - 0.1
Reaction time @ 10 % of IP N tra s - 0.3 - - 0.3 - - 0.3 - RL = 1 k, di/dt = 50 A/s
Step response time to 90 % of IP N tr s - 0.4 - - 0.4 - - 0.4 - RL = 1 k, di/dt = 50 A/s
Frequency bandwidth (3 dB) BW kHz - 300 - - 300 - - 300 - RL = 1 k
Overall accuracy XG % of IP N - 2.25 - - 1.6 - - 1.8 -
Accuracy X % of IP N - 0.5 - - 0.5 - - 0.5 -
Ambient operating temperature TA C -40 - 105 -40 - 105 -40 - 105
Ambient storage temperature TS C -55 - 125 -55 - 125 -55 - 125
Mass m g - 10 - - 10 - - 10 -