Specifications
working temperature:
-10℃~+80℃
Current Range:
±900A
Voltage - Supply:
±15V
Band Width:
50kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
HAS500-S
Package:
Through Hole
Key Attributes
Model Number: HAS500-S
Product Description

Product Overview

The LEM HAS 50..600-S is a current transducer for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits. It features a Hall effect measuring principle and an insulating plastic case made of polycarbonate PBT. Key advantages include easy mounting, low power consumption, small size, a single design for wide current ratings, and high immunity to external interference. This transducer is designed for industrial applications such as AC variable speed drives, static converters for DC motor drives, battery supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), and power supplies for welding applications.

Product Attributes

  • Brand: LEM
  • Material: Insulating plastic case made of polycarbonate PBT recognized according to UL 94-V0
  • Certifications: UL 94-V0, EN 50178, UL 508, EN 50178: 1997, IEC 61010-1
  • Application Domain: Industrial

Technical Specifications

TypePrimary nominal rms current IPN (A)Primary current measuring range IPM (A)Supply voltage (5 %) UCCurrent consumption ICInsulation resistance @ 500 V DCOutput voltage (Analog) @ IPN, RL = 10 k, TA = 25 COutput internal resistanceLoad resistance RL 2)Accuracy @ IPN, TA = 25 C (excluding offset)Linearity error 3) (0 .. IPN)Electrical offset voltage, TA = 25 C VOEHysteresis offset voltage @ IP = 0, after an excursion of 1 IPN VOHTemperature coefficient of VOETemperature coefficient of Vout (% of reading)Step response time to 90 % of IPNdi/dt accurately followedFrequency bandwidth (-3 dB) 4)Ambient operating temperatureAmbient storage temperatureMassUd Rms voltage for AC insulation test, 50 Hz/1 minW Impulse withstand voltage 1.2/50 sMin dCp Creepage distancedCI ClearanceCTI Comparative tracking index (group IIIa)
HAS 50-S5015015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<2 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 100-S10030015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 200-S20060015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 300-S30090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 400-S40090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 500-S50090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275
HAS 600-S60090015 V15 mA>1000 M4 Vapprox 100 >1 k<1 % of IPN<1 % of IPN<20 mV<20 mV<1 mV/K<0.1 %/K<3 s>50 A/sDC .. 50 kHz-10 .. +80 C-25 .. +80 Capprox 60 g3.6 kV>6.6 kV7.08 mm6.23 mm275