Current Transducer HTFS 200 ... 800-P
The HTFS 200-800-P is a current transducer designed for the electronic measurement of DC, AC, and pulsed currents, providing galvanic separation between the primary and secondary circuits. It features a Hall effect measuring principle, low power consumption, a single +5V power supply, and a ratiometric offset. The transducer is housed in an insulating plastic case recognized according to UL 94-V0 and is fastened by M3 nuts and screws. Its compact size, wide current rating range, and high immunity to external interference make it suitable for various industrial applications such as forklift drives, AC variable speed drives, and power supplies for welding applications.
Product Attributes
- Brand: LEM
- Origin: (Not specified)
- Material: Insulating plastic case (UL 94-V0)
- Color: (Not specified)
- Certifications: UL 94-V0, EN 50178, IEC 61010-1
Technical Specifications
| Model | Primary Nominal Current (IP N) | Primary RMS Current Measuring Range (IP) | Output Voltage (Analog) @ IP (Uout) | Reference Voltage (Uref) | Supply Voltage (UC) | Current Consumption @ UC = 5 V | Total Error (tot) @ IP N, TA = 25 C | Linearity Error (L) 0 ... 1.5 IP N | Magnetic Offset Voltage (UO M) @ IP = 0 | Output Voltage Noise (uno) (DC ... 20 MHz) | Delay Time to 10% (tD 10) for IP N step | Delay Time to 90% (tD 90) for IP N step | di/dt accurately followed | Frequency Bandwidth (BW) (3 dB) | Ambient Operating Temperature (TA) | Mass (m) |
| HTFS 200-P | 300 A | 300 A | (1.25 IP/IP N) V | 0.025 V | 5 V (5 %) | 19 (typ) / 25 (max) mA | 1 % | 0.5 % | < 0.5 % | < 40 mVpp | < 2 s | < 3.5 s | > 100 A/s | DC ... 240 kHz | 40 ... +105 C | 60 g |
| HTFS 400-P | 600 A | 600 A | (1.25 IP/IP N) V | 0.025 V | 5 V (5 %) | 19 (typ) / 25 (max) mA | 1 % | 0.5 % | < 0.5 % | < 40 mVpp | < 2 s | < 3.5 s | > 100 A/s | DC ... 240 kHz | 40 ... +105 C | 60 g |
| HTFS 600-P | 900 A | 900 A | (1.25 IP/IP N) V | 0.025 V | 5 V (5 %) | 19 (typ) / 25 (max) mA | 1 % | 0.5 % | < 0.5 % | < 40 mVpp | < 2 s | < 3.5 s | > 100 A/s | DC ... 240 kHz | 40 ... +105 C | 60 g |
| HTFS 800-P | 1200 A | 1200 A | (1.25 IP/IP N) V | 0.025 V | 5 V (5 %) | 19 (typ) / 25 (max) mA | 1 % | 0.5 % | < 0.5 % | < 40 mVpp | < 2 s | < 3.5 s | > 100 A/s | DC ... 240 kHz | 40 ... +105 C | 60 g |