Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Current transducer LEM HTFS 200-P with single 5 volt power supply and high immunity to external interference factory
<
quality Current transducer LEM HTFS 200-P with single 5 volt power supply and high immunity to external interference factory
>
Specifications
working temperature:
-40℃~+105℃
Current Range:
200A
Voltage - Supply:
5V
Band Width:
240kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
HTFS 200-P
Key Attributes
Model Number: HTFS 200-P
Product Description

Current Transducer HTFS 200 ... 800-P

The HTFS 200-800-P is a current transducer designed for the electronic measurement of DC, AC, and pulsed currents, providing galvanic separation between the primary and secondary circuits. It features a Hall effect measuring principle, low power consumption, a single +5V power supply, and a ratiometric offset. The transducer is housed in an insulating plastic case recognized according to UL 94-V0 and is fastened by M3 nuts and screws. Its compact size, wide current rating range, and high immunity to external interference make it suitable for various industrial applications such as forklift drives, AC variable speed drives, and power supplies for welding applications.

Product Attributes

  • Brand: LEM
  • Origin: (Not specified)
  • Material: Insulating plastic case (UL 94-V0)
  • Color: (Not specified)
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1

Technical Specifications

ModelPrimary Nominal Current (IP N)Primary RMS Current Measuring Range (IP)Output Voltage (Analog) @ IP (Uout)Reference Voltage (Uref)Supply Voltage (UC)Current Consumption @ UC = 5 VTotal Error (tot) @ IP N, TA = 25 CLinearity Error (L) 0 ... 1.5 IP NMagnetic Offset Voltage (UO M) @ IP = 0Output Voltage Noise (uno) (DC ... 20 MHz)Delay Time to 10% (tD 10) for IP N stepDelay Time to 90% (tD 90) for IP N stepdi/dt accurately followedFrequency Bandwidth (BW) (3 dB)Ambient Operating Temperature (TA)Mass (m)
HTFS 200-P300 A300 A(1.25 IP/IP N) V0.025 V5 V (5 %)19 (typ) / 25 (max) mA 1 % 0.5 %< 0.5 %< 40 mVpp< 2 s< 3.5 s> 100 A/sDC ... 240 kHz40 ... +105 C60 g
HTFS 400-P600 A600 A(1.25 IP/IP N) V0.025 V5 V (5 %)19 (typ) / 25 (max) mA 1 % 0.5 %< 0.5 %< 40 mVpp< 2 s< 3.5 s> 100 A/sDC ... 240 kHz40 ... +105 C60 g
HTFS 600-P900 A900 A(1.25 IP/IP N) V0.025 V5 V (5 %)19 (typ) / 25 (max) mA 1 % 0.5 %< 0.5 %< 40 mVpp< 2 s< 3.5 s> 100 A/sDC ... 240 kHz40 ... +105 C60 g
HTFS 800-P1200 A1200 A(1.25 IP/IP N) V0.025 V5 V (5 %)19 (typ) / 25 (max) mA 1 % 0.5 %< 0.5 %< 40 mVpp< 2 s< 3.5 s> 100 A/sDC ... 240 kHz40 ... +105 C60 g

2411261442_LEM-HTFS-200-P_C7285735.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible