Online Service

Online Service

Contact Person
+86 136 6733 2386
quality High accuracy isolated current sensor LEM LT208-S7 designed for DC AC and pulse current applications factory
<
quality High accuracy isolated current sensor LEM LT208-S7 designed for DC AC and pulse current applications factory
>
Specifications
working temperature:
-10℃~+70℃
Current Range:
±300A
Voltage - Supply:
-15V~-12V;12V~15V
Band Width:
100kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
LT208-S7
Key Attributes
Model Number: LT208-S7
Product Description

Product Overview

The LEM LT 208-S7 is an isolated current sensor designed for measuring DC, AC, and pulse currents. It offers excellent accuracy, linearity, low temperature drift, and fast response times, making it suitable for a wide range of industrial applications including variable speed drives, servo motors, and power supplies.

Product Attributes

  • Brand: LEM
  • Model: LT 208-S7
  • Certifications: EN 50178, UL 94-V0 (insulation housing)
  • Origin: China (implied by Shanghai Jiaren mention)

Technical Specifications

ParameterValueUnitNotes
Primary Rated RMS Current (IPN)200A
Primary Current Measuring Range (IPM)0 .. 300A
Secondary Rated RMS Current (ISN)100mA
Conversion Ratio (KN)1 : 2000
Supply Voltage (VC) 12 .. 15V( 5 %)
Current Consumption (IC)28 (@ 12V) + ISmA
Total Accuracy @ IPN, TA = 25C (XG) 0.5%
Linearity (L)< 0.1%Typ
Zero Offset Voltage @ IP = 0, TA = 25C (IO) 0.20mA
Magnetic Offset Current (IOM) 0.20mA@ IP = 0, overload through 3 x IPN
Temperature Drift of IO (IOT) 0.20 .. 0.64mA(- 10C .. + 70C)
Response Time to 10% of IPN (tra)< 500ns
Response Time to 90% of IPN (tr)< 1s2)
di/dt Following Accuracy> 100A/s
Bandwidth (- 3 dB) (BW)DC .. 100kHz
Ambient Operating Temperature (TA)- 10 .. + 70C
Ambient Storage Temperature (TS)- 25 .. + 80C
Secondary Coil Resistance @ TA = 70C (RS)21
Mass (m)79g
AC Isolation Test Voltage (Vd)3.52kV50 Hz, 1 min, primary-secondary
Impulse Withstand Voltage (Vw)6.5kV1.2/50 s
Creepage Distance (dCp)10mm2)
Clearance Distance (dCI)6mm2)
Comparative Tracking Index (CTI)275(group IIIa)
Load Voltage CategoryOV 3According to EN 50178
Pollution DegreePD2According to EN 50178