Product Overview
The LEM LF 205-S is a closed-loop (compensated) current transducer utilizing Hall effect technology. It is designed for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between the primary and secondary circuits. Key advantages include excellent accuracy, very good linearity, low temperature drift, optimized response time, and a wide frequency bandwidth, making it suitable for industrial applications such as AC variable speed drives, servo motor drives, static converters, battery-supplied applications, UPS, SMPS, and welding power supplies.
Product Attributes
- Brand: LEM
- Origin: Switzerland
- Material: Insulating plastic case recognized according to UL 94-V0
- Certifications: UL 94-V0, EN 50178, IEC 61010-1
Technical Specifications
| Specification | Value |
| Primary Nominal RMS Current (IP N) | 200 A |
| Primary Current Measuring Range | 0 ... 420 A |
| Secondary Nominal RMS Current (IS N) | 100 mA |
| Turns Ratio (NP/NS) | 1 : 2000 |
| Supply Voltage (UC) | 12 ... 15 V |
| Current Consumption (@ 15 V) | 17 + IS mA |
| Total Error (@ IP N, TA = 25 C) | 0.5 % |
| Linearity Error | < 0.1 % |
| Offset Current (@ IP = 0, TA = 25 C) | 0.2 mA |
| Magnetic Offset Current (after 3x IP N overload) | 0.1 mA |
| Temperature Variation of IO | 0.12 to 0.4 mA |
| Delay Time to 10% of IP N | < 500 ns |
| Delay Time to 90% of IP N | < 1 s |
| Frequency Bandwidth (3 dB) | DC ... 100 kHz |
| Ambient Operating Temperature (TA) | 40 ... +85 C |
| Ambient Storage Temperature (TA st) | 40 ... +90 C |
| Mass | 78 g |
| RMS Voltage for AC Insulation Test (Ud RMS) | 3.5 kV |
| Impulse Withstand Voltage (UNi) | 8.8 kV |
| Partial Discharge Extinction Voltage (Ue) | > 2 kV |
| Creepage Distance (dCp) | 11 mm |
| Clearance (dCI) | 10.2 mm |
| CTI | 175 |
| Primary Through-hole Diameter | 15.5 mm |