quality Closed loop Hall effect current transducer LEM LA200-P for industrial DC AC and pulsed current applications factory
<
quality Closed loop Hall effect current transducer LEM LA200-P for industrial DC AC and pulsed current applications factory
>
Specifications
working temperature:
-40℃~+85℃
Current Range:
±300A
Voltage - Supply:
-15V~-12V;12V~15V
Band Width:
100kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
LA200-P
Package:
Through Hole
Key Attributes
Model Number: LA200-P
Product Description

Product Overview

The LEM LA 200-P is a closed-loop Hall effect current transducer designed for the electronic measurement of DC, AC, and pulsed currents with galvanic separation between primary and secondary circuits. It offers excellent accuracy, linearity, low temperature drift, and a wide frequency bandwidth, making it suitable for industrial applications such as AC variable speed drives, static converters, UPS, and power supplies for welding.

Product Attributes

  • Brand: LEM
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1
  • Application Domain: Industrial

Technical Specifications

SpecificationValueNotes
Primary Nominal Current (IPN)200 A rms
Primary Current Measuring Range (IPM)0 .. 300 A
Secondary Nominal Current (ISN)100 mA rms
Conversion Ratio (KN)1 : 2000
Supply Voltage (UC) 12 .. 15 V ( 5 %)
Current Consumption (IC)16 mA (@ 15 V) + IS
Accuracy @ IPN, TA = 25C, 15 V 0.40 %
Accuracy @ IPN, TA = 25C, 12 .. 15 V 0.65 %
Linearity Error (L)< 0.15 %Typ Max
Offset Current (IO) @ IP = 0, TA = 25C 0.20 mA
Magnetic Offset Current (IOM) 0.25 mA@ IP = 0 and specified RM, after an overload of 3 x IPN
Temperature Variation of IO (0C .. +70C) 0.10 .. 0.25 mA
Temperature Variation of IO (-40C .. +85C) 0.15 .. 0.55 mA
Reaction Time (tra)< 500 ns
Step Response Time (tr) to 90% of IPN< 1 sWith a di/dt of 100 A/s
di/dt Accurately Followed> 200 A/sPrimary conductor best filling hole and/or return above transducer
Frequency Bandwidth (- 1 dB) (BW)DC .. 100 kHz
Ambient Operating Temperature (TA)- 40 .. + 85 C
Ambient Storage Temperature (TS)- 40 .. + 90 C
Secondary Coil Resistance (RS) @ TA = 70C76
Secondary Coil Resistance (RS) @ TA = 85C80
Mass40 g
Rms Voltage for AC Insulation Test (Ud)3 kV50 Hz, 1 min
Impulse Withstand Voltage (W)7 kV1.2/50 s
Partial Discharge Extinction Voltage (Ue)> 1.8 kV rms@ 10 pc
Creepage Distance (dCp)6.7 mm
Clearance (dCI)6.7 mm
Comparative Tracking Index (CTI)175(group IIIa)
Rated Insulation Voltage (EN 50178)600 VBasic insulation
Rated Insulation Voltage (EN 50178)300 VReinforced insulation
Nominal Voltage (IEC 61010-1)600 VBasic insulation
Nominal Voltage (IEC 61010-1)300 VReinforced insulation
Primary Through-hole17 x 11 mm
Secondary Connection4 pins 0.63 x 0.56 mmRecommended PCB hole 0.9 mm
Supplementary Fastening2 holes 1.75 mmRecommended PCB hole 2.4 mm
Recommended ScrewsPT KA 22 x 6Recommended fastening torque 0.5 Nm

2410121619_LEM-LA200-P_C453477.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max