Online Service

Online Service

Contact Person
+86 136 6733 2386
quality LEM LA150-P current transducer providing measurement for UPS SMPS welding and DC motor drive power supplies factory
<
quality LEM LA150-P current transducer providing measurement for UPS SMPS welding and DC motor drive power supplies factory
>
Specifications
working temperature:
-40℃~+85℃
Current Range:
±212A
Voltage - Supply:
-15V~-12V;12V~15V
Band Width:
150kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
LA150-P
Package:
Through Hole,37x16mm
Key Attributes
Model Number: LA150-P
Product Description

Product Description

The LA 150-P is a closed-loop (compensated) current transducer utilizing the Hall effect. It is designed for the electronic measurement of currents including DC, AC, and pulsed currents, providing galvanic separation between the primary and secondary circuits. Key advantages include excellent accuracy, very good linearity, low temperature drift, optimized response time, and a wide frequency bandwidth. It offers no insertion losses and high immunity to external interference, along with current overload capability. This transducer is ideal for applications such as AC variable speed drives, static converters for DC motor drives, battery-supplied applications, Uninterruptible Power Supplies (UPS), Switched Mode Power Supplies (SMPS), and power supplies for welding applications within the industrial domain.

Product Attributes

  • Brand: LEM
  • Certifications: UL 508, CSA C22.2 NO. 14, EN 50178, IEC 61010-1
  • Material: Insulating plastic case recognized according to UL 94-V0

Technical Specifications

ParameterSymbolUnitValueNotes
Primary nominal rms currentIPNA150
Primary current, measuring rangeIPMA0 .. 212
Measuring resistance @ 85 CRM0 - 40 (@ 150 A max), 0 - 3 (@ 212 A max) with 12 V; 0 - 78 (@ 150 A max), 0 - 30 (@ 212 A max) with 15 V
Secondary nominal rms currentISNmA75
Conversion ratioKN1 : 2000
Supply voltageUCV DC12 .. 15(5 %)
Current consumptionICmA10 (@ 15 V) + IS
Accuracy @ IPN, TA = 25 C%<0.5
Linearity error%<0.1Typ
Electrical offset current @ IP = 0, TA = 25 CIOEmA0.10
Magnetic offset current @ IP = 0 and specified RM, after an overload of 3 IPNIOMmA0.25
Temperature variation of IOIOTmA0.15 (Typ), 0.30 (Max)-40 C .. +85 C
Reaction timetrans<300
Step response time (1) to 90 % of IPNtrns<500With a di/dt of 100 A/s.
di/dt accurately followeddi/dtA/s>100
Frequency bandwidth (-1 dB)BWkHzDC .. 150
Ambient operating temperatureTAC-40 .. +85
Ambient storage temperatureTSC-40 .. +90
Resistance of secondary winding @ TA = 25 CRS642
Massg<25
Rms voltage for AC insulation test, 50 Hz/1 minUdkV4.3
Impulse withstand voltage 1.2/50 sWkV8
Partial discharge extinction rms voltage @ 10 pCUekV1.3
Min creepage distancedCpmm8
ClearancedCImm8
Comparative tracking index (group I)CTI600
Primary potential involvedV AC/DC600
Max surrounding air temperatureTAC85
Secondary supply voltageUCV DC12 .. 15
Output signalISNmA75

2410121717_LEM-LA150-P_C5891287.pdf