Product Overview
The LEM HO-P series are Hall effect current transducers designed for the electronic measurement of DC, AC, and pulsed currents. They provide galvanic separation between the primary and secondary circuits, offering a compact, space-saving solution with high insulation capability and fast response. These transducers are ideal for applications requiring precise current measurement with a single power supply and features like over-current detection.
Product Attributes
- Brand: LEM
- Product Series: HO-P
- Certifications: EN 50178, IEC 61010-1, IEC 61326-1, UL 508, CSA C22.2 NO. 14-10
- Application Domain: Industrial
Technical Specifications
| Parameter | Symbol | Unit | IPN = 6 A | IPN = 10 A | IPN = 25 A | Comment |
|---|---|---|---|---|---|---|
| Primary nominal rms current | IPN | A | 6 | 10 | 25 | |
| Primary current, measuring range | IPM | A | -20 to 20 | -25 to 25 | -62.5 to 62.5 | |
| Supply voltage | UC | V | 4.5 to 5.5 | 4.5 to 5.5 | 4.5 to 5.5 | +5 V single supply |
| Current consumption | IC | mA | 19 to 25 | 19 to 25 | 19 to 25 | |
| Reference voltage | Vref | V | 2.475 to 2.525 | 2.475 to 2.525 | 2.475 to 2.525 | Internal reference |
| Output voltage range @ IPM | VOUT - Vref | V | -2 to 2 | -2 to 2 | -2 to 2 | |
| Electrical offset voltage | VOE | mV | -10 to 10 | -10 to 10 | -10 to 10 | |
| Theoretical sensitivity | Gth | mV/A | 100 to 600 | 80 to 800 | @ IPN, @ UC = 5 V | |
| Sensitivity error | G | % | 0.85 | 0.85 | Factory adjustment | |
| Linearity error (0 .. IPN) | L | % of IPN | 0.5 | 0.5 | @ UC = 5 V | |
| Magnetic offset voltage @ IP = 0 after 2.5 IPN | VOM | mV | 5 | 6 | ||
| Reaction time @ 10 % of IPN | tra | s | 2 | 2 | di/dt = IPN/s | |
| Response time @ 90 % of IPN | tr | s | 3.5 | 3.5 | di/dt = IPN/s | |
| Frequency bandwidth (-3 dB) | BW | kHz | 250 | 250 | ||
| Output voltage noise (spectral density) (DC .. 100 kHz) | eno | Vrms/Hz | 32.9 | @ UC = 5 V | ||
| Output voltage noise (DC .. 20 MHz) | Vno | mVpp | 80 | 50 | ||
| Over-current detect | V | 2.6 IPN to 3.2 IPN (peak value) | 2.6 IPN to 3.2 IPN (peak value) | 2.6 IPN to 3.2 IPN (peak value) | ||
| Accuracy @ IPN | X | % of IPN | 1.35 | 1.35 | G + L | |
| Accuracy @ IPN @ TA = +85C | X | % of IPN | 4.25 | 3.75 | See formula note 1) | |
| Accuracy @ IPN @ TA = +105C | X | % of IPN | 5.22 | 4.55 | See formula note 1) | |
| Insulated test voltage (RMS) | Ud | kV | 4.3 | 4.3 | 4.3 | 50/60 Hz/1 min |
| Impulse withstand voltage | W | kV | 8 | 8 | 8 | 1.2/50 s |
| Partial discharge extinction voltage @ 10 pC (rms) | Ue | V | 1650 | 1650 | 1650 | |
| Clearance (pri. - sec.) | dCI | mm | 8 | 8 | 8 | Shortest distance through air |
| Creepage distance (pri. - sec.) | dCp | mm | 8 | 8 | 8 | Shortest path along device body |
| Ambient operating temperature | TA | C | -40 to 105 | -40 to 105 | -40 to 105 | |
| Ambient storage temperature | TS | C | -40 to 105 | -40 to 105 | -40 to 105 | |
| Mass | m | g | 10 | 10 | 10 |