Specifications
working temperature:
-10℃~+80℃
Current Range:
±1.5kA
Voltage - Supply:
±15V
Band Width:
25kHz
Response Time (tr):
5us
Bidirectional Current Detection:
Support
Mfr. Part #:
Hat500-s
Key Attributes
Model Number: hat500-s
Product Description

Product Overview

The LEM HAT 200..1500-S is a current transducer utilizing the Hall effect principle for the electronic measurement of DC, AC, and pulsed currents. It offers galvanic isolation between the primary (high power) and secondary (electronic) circuits, making it suitable for a wide range of industrial applications. Key advantages include easy installation, small size, and high immunity to external interference.

Product Attributes

  • Brand: LEM
  • Certifications: UL 94-V0 recognized plastic case, EN 50178, IEC 61010-1
  • Material: Isolated plastic case

Technical Specifications

TypePrimary Nominal Current (IPN) (A)Primary Measuring Range (IPM) (A)Supply Voltage (VC) ( 5 %)Current Consumption (IC)Isolation Resistance (@ 500 VDC)Output Voltage (VOUT) (@ IPN, RL =10 k, TA = 25C)Load Resistance (RL)Accuracy (@ IPN, TA = 25C)Linearity Error (L) (0 .. IPN)Electrical Offset Voltage (VOE) (@ TA = 25C)Hysteresis Offset Voltage (VOH) (@ IP = 0, after an excursion of 1 x IPN)Temp. Coefficient of VOE (TCVOE)Temp. Coefficient of VOUT (TCVOUT) (% of reading)Response Time to 90% of IPN step (tr)Frequency Bandwidth (BW) (- 3 dB)Ambient Operating Temperature (TA)Ambient Storage Temperature (TS)Mass (m)Isolation Voltage (Vd) Rms voltage for AC isolation test, 50 HZ, 1 minImpulse Withstand Voltage (Vw) 1.2/50 sCreepage Distance (dCp)Clearance Distance (dCI)Comparative Tracking Index (CTI)
HAT 200-S200 600 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 400-S400 1200 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 500-S500 1500 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 600-S600 1800 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 800-S800 2400 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 1000-S1000 2500 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 1200-S1200 2500 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 1500-S1500 2500 15 V 15 mA> 1000 M 4 V> 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275