Online Service

Online Service

Contact Person
+86 136 6733 2386
quality hall effect current transducer LEM hat1000-s for dc ac and pulsed currents in industrial environments factory
<
quality hall effect current transducer LEM hat1000-s for dc ac and pulsed currents in industrial environments factory
>
Specifications
working temperature:
-10℃~+80℃
Current Range:
±2.5kA
Voltage - Supply:
±15V
Band Width:
25kHz
Bidirectional Current Detection:
Support
Mfr. Part #:
Hat1000-s
Key Attributes
Model Number: hat1000-s
Product Description

Product Overview

The LEM HAT 200..1500-S is a current transducer designed for the electronic measurement of DC, AC, and pulsed currents with galvanic isolation between the primary and secondary circuits. It utilizes the Hall effect measuring principle and offers features like low power consumption, an extended measuring range, and an isolated plastic case recognized according to UL 94-V0. Its advantages include easy installation, small size, space-saving design, a single design for wide current ratings, and high immunity to external interference, making it suitable for various industrial applications such as DC motor drives, Switched Mode Power Supplies (SMPS), AC variable speed drives, Uninterruptible Power Supplies (UPS), battery-supplied applications, and power supplies for welding.

Product Attributes

  • Brand: LEM
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1
  • Application Domain: Industrial

Technical Specifications

TypePrimary nominal current, rms (IPN)Primary current measuring range (IPM)Supply voltage (VC)Current consumption (IC)Isolation resistance @ 500 VDCOutput voltage (VOUT) @ IPN, RL =10 k, TA = 25COutput internal resistance (ROUT)Load resistance (RL)Accuracy @ IPN, TA = 25C (excluding offset)Linearity error (L) (0 .. IPN)Electrical offset voltage (VOE) @ TA = 25CHysteresis offset voltage (VOH) @ IP = 0, after an excursion of 1 x IPNTemperature coefficient of VOETemperature coefficient of VOUT (% of reading)Response time to 90% of IPN stepFrequency bandwidth (- 3 dB)Ambient operating temperature (TA)Ambient storage temperature (TS)MassRms voltage for AC isolation test, 50 Hz, 1 min (Vd)Impulse withstand voltage 1.2/50 s (Vw)Creepage distance (dCp)Clearance distance (dCI)Comparative Tracking Index (CTI)
HAT 200-S200 A 600 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 400-S400 A 1200 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 500-S500 A 1500 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 600-S600 A 1800 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 800-S800 A 2400 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 1000-S1000 A 2500 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 1200-S1200 A 2500 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275
HAT 1500-S1500 A 2500 A 15 V ( 5 %) 15 mA> 1000 M 4 V100 > 10 k 1 % of IPN 1 % of IPN< 20 mV< 10 mV< 1 mV/K< 0.1 %/K< 5 sDC .. 25 kHz- 10 .. + 80 C- 25 .. + 85 C300 g4.9 kV> 9.0 kV9.9 mm9.9 mm275

2410121623_LEM-hat1000-s_C444904.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max