Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Industrial DC current sensor Isabellenhuette IVT-S-100-U3-I-CAN2-12/24 with modular design and CAN 2.0a interface factory
<
quality Industrial DC current sensor Isabellenhuette IVT-S-100-U3-I-CAN2-12/24 with modular design and CAN 2.0a interface factory
quality Industrial DC current sensor Isabellenhuette IVT-S-100-U3-I-CAN2-12/24 with modular design and CAN 2.0a interface factory
quality Industrial DC current sensor Isabellenhuette IVT-S-100-U3-I-CAN2-12/24 with modular design and CAN 2.0a interface factory
>
Specifications
working temperature:
-40℃~+105℃
Current Range:
±100A
Voltage - Supply:
5.5V~40V
Mfr. Part #:
IVT-S-100-U3-I-CAN2-12/24
Key Attributes
Model Number: IVT-S-100-U3-I-CAN2-12/24
Product Description

Product Overview

The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive and industrial sectors. It features a modular design for flexibility and offers continuous current measurement up to 2500 A, with automatic range extension for higher peak currents. Utilizing a shunt-based method with a 16-bit ADC and CAN 2.0a communication, it ensures fast system integration.

Product Attributes

  • Brand: Isabellenhtte
  • Material: UL94-V0 for Housing, Connectors, and PCB
  • Certifications: DIN EN 60664-1:2008-01 (Isolation Voltage), UL94-V0
  • Origin: Not specified
  • Color: Not specified

Technical Specifications

FeatureSpecification
Measurement MethodShunt-based with 16-bit ADC
Communication InterfaceCAN 2.0a
Current Measurement RangeUp to 2500 A (continuous), automatic range extension for peaks
Measurement ModesDisable, Trigger, Cycle running
Output SignalsCurrent (A), Voltage (V), Temperature (C), Power (W), Current Counter (As), Energy Counter (Wh)
Internal SafetySensor status monitoring, dual ADC verification for current measurement, ADC reference voltage monitoring
Log Data StorageContinuous storage at 15-minute intervals (if configured in run-mode)
Galvanic IsolationIsolation module for different potential levels (low voltage side and high voltage side). Isolation Voltage: 1000V RMS CATI / 600V RMS CATII / 300V RMS CATIII (Max Working). Basis Isolation DC Voltage: 1000 V. Reinforced Isolation DC Voltage: 600 V. Highest allowed transient overvoltage: 6000V (for 1s). Minimum External Clearance: > 40 mm. Minimum External Creepage: > 50 mm. Minimum Internal Clearance: 8 mm. Material Group housing: IIIa. Material Group connectors: II.
FlammabilityUL94-V0 compliant for Housing, Connectors, and PCB
Sampling RatesCurrent: Max output rate of 1 message per 1ms. Voltage: Multiplexed on ADC2.

2411272239_Isabellenhuette-IVT-S-100-U3-I-CAN2-12-24_C5657855.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max