Specifications
working temperature:
-40℃~+105℃
Current Range:
±300A
Voltage - Supply:
5.5V~40V
Mfr. Part #:
IVT-S-300-U3-I-CAN2-12/24
Key Attributes
Model Number: IVT-S-300-U3-I-CAN2-12/24
Product Description

IVT-S High Precision Current Measurement System

The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive sector. Its modular design offers flexibility for rapid adaptation to customer requirements in both automotive and industrial environments. The system utilizes a shunt-based measurement method with a 16-bit analog-to-digital converter and communicates via a CAN bus 2.0a interface, with a CAN description file (CAN-dbc) available for streamlined integration.

Product Attributes

  • Brand: Isabellenhtte
  • Certifications: UL94-V0 materials (Housing, Connectors, PCB); DIN EN 60664-1:2008-01 (Galvanic Isolation)
  • Material: UL94-V0 rated for Housing, Connectors, and PCB

Technical Specifications

Item Unit Min Max
Continuous Current Measurement Range A 2500
Current Measurement Max (Log Data) A -32.000 +32.000
Current Measurement Min (Log Data) A -32.000 +32.000
U1 Measurement Max (Log Data) V -32.000 +32.000
U1 Measurement Min (Log Data) V -32.000 +32.000
U2 Measurement Max (Log Data) V -32.000 +32.000
U2 Measurement Min (Log Data) V -32.000 +32.000
U3 Measurement Max (Log Data) V -32.000 +32.000
U3 Measurement Min (Log Data) V -32.000 +32.000
Temperature Measurement Max (Log Data) 1/10 C -500 +2000
Temperature Measurement Min (Log Data) 1/10 C -500 +2000
Ampere hour counter overall (Log Data) As -72.000.000.000.000 +72.000.000.000.000
Energy counter overall (Log Data) Wh -72.000.000.000.000 +72.000.000.000.000
Runtime overall (Log Data) s 0 +3.000.000.000
Max Working Isolation Voltage V RMS 600 (CAT II) 1000 (CAT I)
Basis Isolation DC Voltage V 1000
Reinforced Isolation DC Voltage V 600
Highest allowed transient overvoltage V 6000 (for 1s)
Minimum External Clearance distance mm > 40
Minimum External Creepage distance mm > 50