Product Overview
The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive and industrial sectors. Its modular design offers flexibility for customization. Utilizing a shunt-based measurement method with a 16-bit ADC, it provides continuous current measurement up to 2500 A, with automatic range extension for peak currents. Communication is facilitated via a CAN 2.0a interface, supported by a provided CAN description file for rapid system integration.
Product Attributes
- Brand: Isabellenhtte
- Material: UL94-V0 for Housing, Connectors, and PCB
- Certifications: DIN EN 60664-1:2008-01 (Isolation Voltage), UL94-V0 (Flammability)
Technical Specifications
| Item | Unit | Min | Max |
|---|---|---|---|
| Continuous Current Measurement Range | A | -2500 | +2500 |
| ADC Resolution | - | 16-bit | - |
| Communication Interface | - | CAN 2.0a | - |
| Isolation Voltage (Max Working RMS) | V RMS | - | 1000 |
| Isolation Voltage (Max Working CAT II) | V RMS | - | 600 |
| Isolation Voltage (Max Working CAT III) | V RMS | - | 300 |
| Basis Isolation DC Voltage | V DC | - | 1000 |
| Reinforced Isolation DC Voltage | V DC | - | 600 |
| Highest Allowed Transient Overvoltage | V | - | 6000 (for 1s) |
| Minimum External Clearance Distance | mm | - | 40 |
| Minimum External Creepage Distance | mm | - | 50 |
| Minimum Internal Clearance | mm | - | 8 |
| Material Group Housing | - | IIIa | - |
| Material Group Connectors | - | II | - |
| Ampere hour counter overall (if activated) | As | -72.000.000.000.000 | +72.000.000.000.000 |
| Ampere hour counter charging (if activated) | As | 0 | +144.000.000.000.000 |
| Ampere hour counter discharging (if activated) | As | 0 | +144.000.000.000.000 |
| Energy counter overall (if activated) | Wh | -72.000.000.000.000 | +72.000.000.000.000 |
| Energy counter charging (if activated) | Wh | 0 | +144.000.000.000.000 |
| Energy counter discharging (if activated) | Wh | 0 | +144.000.000.000.000 |
| Runtime overall | s | 0 | +3.000.000.000 |
| Runtime current measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime current measurement outside specified limits | s | 0 | +3.000.000.000 |
| Current measurement maximum | A | -32.000 | +32.000 |
| Current measurement minimum | A | -32.000 | +32.000 |
| Temperature measurement maximum (1/10 C) | 1/10 C | -500 | +2000 |
| Temperature measurement minimum (1/10 C) | 1/10 C | -500 | +2000 |
2411272239_Isabellenhuette-IVT-S-2K5-U3-I-CAN2-12-24_C6577881.pdf