Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Analog Absolute Pressure Sensor IC Infineon KP229E3111XTMA1 with Automotive Qualification and Clamping factory
<
quality Analog Absolute Pressure Sensor IC Infineon KP229E3111XTMA1 with Automotive Qualification and Clamping factory
>
Specifications
Absolute Accuracy:
2.5Kpa
Pressure range:
20Kpa~3bar
Function:
Temperature Sensor
Module:
Yes
Response time:
1ms
Mfr. Part #:
KP229E3111XTMA1
Package:
SMD-8P
Key Attributes
Model Number: KP229E3111XTMA1
Product Description

Product Overview

The KP229E3111 is a miniaturized Analog Manifold Air Pressure Sensor IC utilizing a capacitive principle and surface micromachining technology. It integrates a signal conditioning circuit in BiCMOS technology, converting pressure into a ratiometric analog output signal. With a calibrated transfer function, it measures pressure from 20 kPa to 300 kPa, outputting a voltage range of 0.40 V to 4.65 V. This high-accuracy, high-sensitivity sensor is designed for manifold air pressure measurement and is suitable for automotive, industrial, and consumer applications. It features a wide temperature range, broken wire detection, clamping, and is automotive qualified.

Product Attributes

  • Brand: Infineon Technologies
  • Technology: BiCMOS
  • Housing: "Green" 8 pin SMD
  • Qualification: Automotive qualified

Technical Specifications

kPa V V mA mV /kPa kPa kPa mV V V ms ms ms ms kV
Parameter Symbol Value Unit Notes
Product Name - KP229E3111 Analog Absolute Pressure Sensor - -
Product Type - Analog Manifold Air Pressure Sensor IC - -
Ordering Code - SP001031312 - -
Package - PG-DSOF-8-16 - -
Pressure Range (Operating) pamb 20 300 -
Output Voltage Range (Ratiometric) VOUT_R 0.10 4.85 See section Output Voltage versus Load
Supply Voltage (Operating) VDD 4.5 5.5 VOUT is ratiometric to VDD
Supply Current (Typical) IDD 8 10 Peak supply current during power up max. 22 mA
Temperature Range (Operating) Ta -40 140 C -
Sensitivity (Typical) S 15.2 -
Accuracy (Overall Pressure) accp 2.5 0C up to 100 C
Accuracy (Overall Pressure) accp 3.75 @ -40C and @ 140C
Ratiometric Error (Max) ERAT 25 -
Lower Clamping Level (Typical) VCl_low 0.3 -
Upper Clamping Level (Typical) VCl_high 4.7 -
Response Time (Max) tR 1.03 10% to 90% of final output value
Stabilization Time (Max) tS 10 For full accuracy
Power-up Time (Max) tUP 5 90% of final output value
Broken Wire Diagnosis Response Time (Max) tOBD 1 -
ESD Robustness (HBM) VESD 2 According to EIA / JESD22-A114-E

2410121536_Infineon-KP229E3111XTMA1_C3236904.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max