Product Overview
The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive sector. It features a modular design for flexibility and adaptability, offering continuous current measurement up to 2500 A with automatic range extension for higher currents. Utilizing a shunt-based method with a 16-bit ADC and CAN 2.0a communication, it ensures fast system integration. The IVT-S is suitable for hybrid and full electric drives, UPS systems, stationary energy storage, fuel cells, and other battery-based applications.
Product Attributes
- Brand: Isabellenhtte
- Material: UL94-V0 for Housing, Connectors, and PCB
- Certifications: DIN EN 60664-1:2008-01 (Isolation Voltage), UL94-V0 (Flammability)
Technical Specifications
| Item | Unit | Min | Max |
|---|---|---|---|
| Current Measurement Maximum | A | -32.000 | +32.000 |
| Current Measurement Minimum | A | -32.000 | +32.000 |
| U1 Measurement Maximum | V | -32.000 | +32.000 |
| U1 Measurement Minimum | V | -32.000 | +32.000 |
| U2 Measurement Maximum | V | -32.000 | +32.000 |
| U2 Measurement Minimum | V | -32.000 | +32.000 |
| U3 Measurement Maximum | V | -32.000 | +32.000 |
| U3 Measurement Minimum | V | -32.000 | +32.000 |
| Temperature Measurement Maximum (1/10 C) | C | -500 | +2000 |
| Temperature Measurement Minimum (1/10 C) | C | -500 | +2000 |
| Ampere hour counter overall (if activated) | As | -72.000.000.000.000 | +72.000.000.000.000 |
| Ampere hour counter charging (if activated) | As | 0 | +144.000.000.000.000 |
| Ampere hour counter discharging (if activated) | As | 0 | +144.000.000.000.000 |
| Energy counter overall (if activated) | Wh | -72.000.000.000.000 | +72.000.000.000.000 |
| Energy counter charging (if activated) | Wh | 0 | +144.000.000.000.000 |
| Energy counter discharging (if activated) | Wh | 0 | +144.000.000.000.000 |
| Runtime overall | s | 0 | +3.000.000.000 |
| Runtime current measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime current measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 1 measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 1 measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 2 measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 2 measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 3 measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 3 measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime temperature measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime temperature measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime OC positive activated | s | 0 | +3.000.000.000 |
| Runtime OC negative activated | s | 0 | +3.000.000.000 |
| Max Working Isolation Voltage | RMS | 600V CATII | 1000V RMS CATI |
| Basis Isolation DC Voltage | V | 1000 | |
| Reinforced Isolation DC Voltage | V | 600 | |
| Highest allowed transient overvoltage | V | 6000 (for 1s) | |
| Minimum External Clearance distance | mm | > 40 | |
| Minimum External Creepage distance | mm | > 50 | |
| Minimum Internal Clearance | mm | 8 |