Specifications
working temperature:
-40℃~+105℃
Current Range:
±100A
Voltage - Supply:
5.5V~40V
Mfr. Part #:
IVT-S-100-U3-I-CAN1-12/24
Key Attributes
Model Number: IVT-S-100-U3-I-CAN1-12/24
Product Description

Product Overview

The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive sector. Its modular design offers flexibility for rapid adaptation to customer requirements in both automotive and industrial environments. The system utilizes a shunt-based measurement method with a 16-bit analog-to-digital converter and communicates via a CAN bus 2.0a interface. It supports continuous current measurement up to 2500 A, with automatic range extension for higher peak currents.

Product Attributes

  • Brand: Isabellenhtte
  • Material: UL94-V0 for Housing, Connectors, and PCB
  • Certifications: DIN EN 60664-1:2008-01 (Isolation Voltage), UL94-V0 (Flammability)

Technical Specifications

FeatureSpecification
Measurement TypeShunt-based current measurement
Current Measurement RangeUp to 2500 A (with automatic range extension for peaks)
Analog-to-Digital Converter16-bit
Communication InterfaceCAN bus 2.0a
Measurement ModesDisable, Trigger, Cycle running
Output SignalsCurrent (A), Voltage (V), Temperature (C), Power (W), Current counter (As), Energy counter (Wh)
Internal Safety FeaturesSensor status monitoring, redundant ADC for current verification, ADC reference voltage monitoring
Log Data StorageContinual storage at 15-minute intervals (if configured in run-mode), recovery on sensor reset, resettable
Galvanic IsolationIsolation module for different potential levels; Isolation voltage up to 1000V RMS (CATI), 600V RMS (CATI-II), 300V RMS (CATI-III)
Flammability RatingUL94-V0 for Housing, Connectors, and PCB
Firmware UpdateVia implemented bootloader (by Isabellenhtte only)
Maximum Current Measurement (Log) 32.000 A
Maximum Voltage Measurement (Log) 32.000 V
Maximum Temperature Measurement (Log)200.0 C (1/10 C)
Minimum Temperature Measurement (Log)-50.0 C (1/10 C)