Product Overview
The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive and industrial sectors. It features a modular design for flexibility and offers continuous current measurement up to 2500 A with automatic range extension for peak currents. The system utilizes a shunt-based method with a 16-bit ADC and communicates via a CAN 2.0a interface, with a CAN description file (CAN-dbc) available for easy integration. Applications include hybrid and electric drives, UPS systems, energy storage, fuel cells, and battery-based systems.
Product Attributes
- Brand: Isabellenhtte
- Material: Housing, Connectors, and PCB are UL94-V0 certified
- Certifications: DIN EN 60664-1:2008-01 (Isolation voltage)
Technical Specifications
| Item | Unit | Min | Max |
| Continuous Current Measurement Range | A | -2500 | +2500 |
| ADC Resolution | - | 16-bit | - |
| Communication Interface | - | CAN 2.0a | - |
| Isolation Voltage (Max Working RMS) | V RMS | 600 (CAT II) | 1000 (CAT I) |
| Isolation Voltage (Basis DC) | V DC | - | 1000 |
| Isolation Voltage (Reinforced DC) | V DC | - | 600 |
| Highest Allowed Transient Overvoltage | V | - | 6000 (for 1s) |
| Minimum External Clearance Distance | mm | > 40 | - |
| Minimum External Creepage Distance | mm | > 50 | - |
| Minimum Internal Clearance | mm | 8 | - |
| Material Group Housing | - | IIIa | - |
| Material Group Connectors | - | II | - |
| Flammability Rating | - | UL94-V0 | - |
| Current Measurement Maximum (Log Data) | A | -32.000 | +32.000 |
| Current Measurement Minimum (Log Data) | A | -32.000 | +32.000 |
| U1 Measurement Maximum (Log Data) | V | -32.000 | +32.000 |
| U1 Measurement Minimum (Log Data) | V | -32.000 | +32.000 |
| U2 Measurement Maximum (Log Data) | V | -32.000 | +32.000 |
| U2 Measurement Minimum (Log Data) | V | -32.000 | +32.000 |
| U3 Measurement Maximum (Log Data) | V | -32.000 | +32.000 |
| U3 Measurement Minimum (Log Data) | V | -32.000 | +32.000 |
| Temperature Measurement Maximum (1/10 C) | 1/10 C | -500 | +2000 |
| Temperature Measurement Minimum (1/10 C) | 1/10 C | -500 | +2000 |
| Ampere hour counter overall (Log Data) | As | -72.000.000.000.000 | +72.000.000.000.000 |
| Ampere hour counter charging (Log Data) | As | 0 | +144.000.000.000.000 |
| Ampere hour counter discharging (Log Data) | As | 0 | +144.000.000.000.000 |
| Energy counter overall (Log Data) | Wh | -72.000.000.000.000 | +72.000.000.000.000 |
| Energy counter charging (Log Data) | Wh | 0 | +144.000.000.000.000 |
| Energy counter discharging (Log Data) | Wh | 0 | +144.000.000.000.000 |
| Runtime overall (Log Data) | s | 0 | +3.000.000.000 |