Product Overview
The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive sector. Its modular design offers flexibility for rapid adaptation to customer requirements in automotive and industrial environments. Utilizing a shunt-based measurement method with a 16-bit ADC, it provides continuous current measurement up to 2500 A, with automatic range extension for higher peak currents. Communication is facilitated via a CAN bus 2.0a interface, supported by an available CAN description file (CAN-dbc) for quick system integration.
Product Attributes
- Brand: Isabellenhtte
- Certifications: UL94-V0 materials for housing, connectors, and PCB; DIN EN 60664-1:2008-01 for galvanic isolation
- Material: UL94-V0
Technical Specifications
| Feature | Specification |
|---|---|
| Measurement Method | Shunt-based |
| ADC Resolution | 16-bit |
| Continuous Current Range | 2500 A |
| Peak Current Handling | Automatic range extension |
| Communication Interface | CAN bus 2.0a |
| Measurement Modes | Disable, Trigger, Cycle running |
| Output Signals | Current (A), Voltage (V), Temperature (C), Power (W), Current counter (As), Energy counter (Wh) |
| Internal Safety Features | Sensor status monitoring, redundant ADC for current verification, ADC reference voltage monitoring |
| Log Data Storage | Continuous storage at 15-minute intervals (if configured in run-mode) |
| Log Data Items | Ampere hour counters (overall, charging, discharging), Energy counters (overall, charging, discharging), Runtime (overall, within/outside limits for current, voltage, temperature), OC positive/negative activated, Current/Voltage/Temperature min/max measurements |
| Firmware Update | Via implemented bootloader (by Isabellenhtte) |
| Galvanic Isolation | Max Working Isolation Voltage: 1000V RMS (CATI), 600V RMS (CATI-II), 300V RMS (CATI-III) |
| Basis Isolation DC Voltage | 1000 V |
| Reinforced Isolation DC Voltage | 600 V |
| Highest Allowed Transient Overvoltage | 6000V (for 1s) |
| Minimum External Clearance | > 40 mm |
| Minimum External Creepage | > 50 mm |
| Minimum Internal Clearance | 8 mm |
| Material Group (housing) | IIIa |
| Material Group (connectors) | II |
| Flammability | UL94-V0 for Housing, Connectors, PCB |
| Current Measurement Output Rate | Max 1ms |
| Voltage Measurement Multiplexing | Utilizes ADC2, multiplexed for different voltage signals |