Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Current sensor system Isabellenhuette IVT-S-500-U0-I-CAN1-12/24 with UL94 V0 rated PCB and connectors factory
<
quality Current sensor system Isabellenhuette IVT-S-500-U0-I-CAN1-12/24 with UL94 V0 rated PCB and connectors factory
quality Current sensor system Isabellenhuette IVT-S-500-U0-I-CAN1-12/24 with UL94 V0 rated PCB and connectors factory
quality Current sensor system Isabellenhuette IVT-S-500-U0-I-CAN1-12/24 with UL94 V0 rated PCB and connectors factory
>
Specifications
working temperature:
-40℃~+105℃
Current Range:
±500A
Voltage - Supply:
5.5V~40V
Mfr. Part #:
IVT-S-500-U0-I-CAN1-12/24
Key Attributes
Model Number: IVT-S-500-U0-I-CAN1-12/24
Product Description

Product Overview

The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive and industrial sectors. It features a modular design for flexibility and offers continuous current measurement up to 2500 A with automatic range extension for higher peak currents. Utilizing a shunt-based method with a 16-bit ADC, it communicates via a CAN 2.0a interface, supported by a CAN description file for easy integration.

Product Attributes

  • Brand: Isabellenhtte
  • Material: Housing, Connectors, and PCB are UL94-V0 rated.
  • Certifications: DIN EN 60664-1:2008-01 (Isolation voltage standards).

Technical Specifications

ParameterValueUnitNotes
Continuous Current Measurement Range2500AAutomatic range extension for peaks
Measurement MethodShunt-based16-bit ADC
Communication InterfaceCAN 2.0aCAN description file (CAN-dbc) available
Measurement ModesDisable, Trigger, Cycle runningConfigurable per channel
Output SignalsCurrent, Voltage (3 channels), Temperature, Power, Current counter, Energy counterA, V, C, W, As, WhConfigurable output transfer rate and value
Internal Safety FeaturesSensor status monitoring, Dual ADC for current verification, ADC reference voltage monitoringDetects non-valid measurement conditions
Log Data Storage15-minute intervals (if in run-mode)Recoverable on sensor reset
Galvanic IsolationMax Working Isolation Voltage: 1000V RMS (CATI), 600V RMS (CATII), 300V RMS (CATIII)V RMSBasis Isolation DC Voltage: 1000 V, Reinforced Isolation DC Voltage: 600 V
Highest allowed transient overvoltage6000V(for 1s)
Minimum External Clearance distance> 40mm
Minimum External Creepage distance> 50mm
Minimum Internal Clearance8mm
Flammability RatingUL94-V0For Housing, Connectors, PCB
Sampling Rate (Current)1msMax output rate
Sampling Rate (Voltage)2, 5, 10msMultiplexed on ADC2

2411272239_Isabellenhuette-IVT-S-500-U0-I-CAN1-12-24_C6280625.pdf

Request A Quote

Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible

You Can Upload Up To 5 Files And Each File Sized 10M Max