Product Overview
The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive and industrial sectors. It offers a modular design for flexibility and fast adaptation to customer requirements. The system utilizes a shunt-based measurement method with a 16-bit ADC and communicates via a CAN 2.0a interface. It supports continuous current measurement up to 2500 A with automatic range extension for higher currents.
Product Attributes
- Brand: Isabellenhtte
- Certifications: UL94-V0 materials (Housing, Connectors, PCB), DIN EN 60664-1:2008-01
- Material: UL94-V0
- Communication Interface: CAN 2.0a
Technical Specifications
| Item | Unit | Min | Max |
|---|---|---|---|
| Current Measurement Range | A | -2500 | +2500 |
| ADC Resolution | bit | 16 | |
| Communication Protocol | CAN 2.0a | ||
| Isolation Voltage (Max Working RMS) | V RMS | 1000 (CATI), 600 (CATII), 300 (CATIII) | |
| Isolation Voltage (Basis DC) | V DC | 1000 | |
| Isolation Voltage (Reinforced DC) | V DC | 600 | |
| Highest Allowed Transient Overvoltage | V | 6000 (for 1s) | |
| Minimum External Clearance Distance | mm | > 40 | |
| Minimum External Creepage Distance | mm | > 50 | |
| Minimum Internal Clearance | mm | 8 | |
| Material Group Housing | IIIa | ||
| Material Group Connectors | II | ||
| Ampere hour counter overall | As | -72.000.000.000.000 | +72.000.000.000.000 |
| Ampere hour counter charging | As | 0 | +144.000.000.000.000 |
| Ampere hour counter discharging | As | 0 | +144.000.000.000.000 |
| Energy counter overall | Wh | -72.000.000.000.000 | +72.000.000.000.000 |
| Energy counter charging | Wh | 0 | +144.000.000.000.000 |
| Energy counter discharging | Wh | 0 | +144.000.000.000.000 |
| Runtime overall | s | 0 | +3.000.000.000 |
| Runtime current measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime current measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 1 measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 1 measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 2 measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 2 measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 3 measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime voltage 3 measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime temperature measurement within specified limits | s | 0 | +3.000.000.000 |
| Runtime temperature measurement outside specified limits | s | 0 | +3.000.000.000 |
| Runtime oc positive activated | s | 0 | +3.000.000.000 |
| Runtime oc negative activated | s | 0 | +3.000.000.000 |
| Current measurement maximum | A | -32.000 | +32.000 |
| Current measurement minimum | A | -32.000 | +32.000 |
| U1 measurement maximum | V | -32.000 | +32.000 |
| U1 measurement minimum | V | -32.000 | +32.000 |
| U2 measurement maximum | V | -32.000 | +32.000 |
| U2 measurement minimum | V | -32.000 | +32.000 |
| U3 measurement maximum | V | -32.000 | +32.000 |
| U3 measurement minimum | V | -32.000 | +32.000 |
| Temperature measurement maximum | 1/10 C | -500 | +2000 |
| Temperature measurement minimum | 1/10 C | -500 | +2000 |
2411272239_Isabellenhuette-IVT-S-1K-U0-I-CAN2-12-24_C6211391.pdf