Specifications
working temperature:
-40℃~+105℃
Current Range:
±1kA
Voltage - Supply:
5.5V~40V
Mfr. Part #:
IVT-S-1K-U3-I-CAN1-12/24
Key Attributes
Model Number: IVT-S-1K-U3-I-CAN1-12/24
Product Description

Product Overview

The IVT-S is a high-precision current measurement system designed for DC applications, particularly in the automotive sector. Its modular design offers flexibility for rapid adaptation to customer requirements in both automotive and industrial environments. The system utilizes a shunt-based measurement method with a 16-bit analog-to-digital converter and communicates via a CAN bus 2.0a interface. It supports continuous current measurement up to 2500 A, with automatic range extension for higher peak currents.

Product Attributes

  • Brand: Isabellenhtte
  • Certifications: UL94-V0 materials (Housing, Connectors, PCB), DIN EN 60664-1:2008-01 (Galvanic Isolation)
  • Material: UL94-V0

Technical Specifications

FeatureDescriptionValue
Measurement TypeShunt-based current measurementContinuous up to 2500 A, automatic peak range extension
ADC Resolution16-bit
Communication InterfaceCAN bus 2.0aCAN description file (CAN-dbc) available
Measurement ModesDisable, Trigger, Cycle runningConfigurable per channel
Output SignalsCurrent, Voltage (1, 2, 3), Temperature, Power, Current counter, Energy counterConfigurable output transfer rate and value
Internal SafetySensor status monitoring, dual ADC verification for current measurement, ADC reference voltage monitoringDetects non-valid measurement conditions
Log Data StorageContinuous storage at 15-minute intervals (if configured in run-mode)Recoverable on sensor reset, resettable
Galvanic IsolationIsolation module for different potential levelsMax Working Isolation Voltage: 1000V RMS CATI, 600V RMS CATI-II, 300V RMS CATI-III
Basis Isolation DC Voltage: 1000 V
Reinforced Isolation DC Voltage: 600 V
Highest allowed transient overvoltage: 6000V (for 1s)
FlammabilityUL94-V0 materialsHousing, Connectors, PCB
Sampling Rate (Current)Max output rate 1msAverage value calculated over configured interval
Sampling Rate (Voltage)Multiplexed on ADC2Dependent on number of voltage channels and configured output rate