Product Overview
The HT18B20A is a programmable resolution 1-Wire digital thermometer compatible with the DS18B20. It offers 9-bit to 12-bit Celsius temperature measurements with a user-programmable alarm function. Communicating via a single data line, it can also derive power directly from the data line (parasite power), eliminating the need for an external power supply. Each HT18B20A features a unique 64-bit serial code, enabling multiple devices on the same 1-Wire bus. This makes it suitable for applications such as HVAC environmental controls, building and equipment temperature monitoring, and process monitoring systems.
Product Attributes
- Brand: Not specified
- Origin: Not specified
- Material: Not specified
- Color: Not specified
- Certifications: Not specified
Technical Specifications
| Parameter | Symbol | Min | Max | Unit | Notes |
|---|---|---|---|---|---|
| Supply voltage (from power supply element) | UDD | -0.5 | 6.0 | V | |
| Ambient temperature | Ta | -60 | 125 | C | |
| Supply voltage | UDD | 3.0 | 5.5 | V | |
| Supply voltage (on external pull-up resistor) in supply mode on DQ (UDD = 0 V) | UPU | 3.0 | 5.5 | V | 1, 2 |
| Low level input voltage at UDD = 5 V | UIL | -0.3 | 0.8 | V | 1, 3 |
| Low level input voltage at UDD = 3 V | UIL | -0.3 | 0.5 | V | 1, 2, 3 |
| High level input voltage in supply mode on VDD pin | UIH | 2.2 | UDD+0.3 | V | 1, 4 |
| High level input voltage in supply mode on DQ (UDD = 0 V) | UIH | 3.0 | UDD+0.3 | V | 1, 2, 4 |
| Cycle time of EEPROM record | tWR | 10 | ms | 2 | |
| Operating ambient temperature | Ta | -55 | 125 | C | |
| Consumption current | IDD | 1.0 | A | 251 C, at 0 V UI 0.4 V or 1.1 V UI UDD-0.3 V | |
| Dynamic Consumption current | IODD | 1500 | A | 251 C, at UDD = 5 V | |
| Low level output current | IOL | 4.0 | mA | at UO = 0.4 V | |
| Input current on DQ pin (Line driver off) | IDQ | 5 | A | 2510 C, UDD = 5 V | |
| Consumption current | IDD | 0.75 | A | 2510 C, at 0 V UI 0.4 V or 0.75 V UI UDD-0.3 V | |
| Temperature measurement drift | T | 0.2 | C | After 1000 hours at 125 C, UDD = 5.5 V | |
| Temperature measurement error | tERR | 0.5 | C | 0 to 85 C | |
| Temperature measurement error | tERR | 2.0 | C | -55 to 125 C |
2409291004_HTCSEMI-HT18B20ARTZ_C2998010.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible