Online Service

Online Service

Contact Person
+86 136 6733 2386
quality temperature detection Honeywell HEL-716-U-0-24-00 thin film platinum RTD with compact ceramic packaging factory
<
quality temperature detection Honeywell HEL-716-U-0-24-00 thin film platinum RTD with compact ceramic packaging factory
>
Specifications
Mfr. Part #:
HEL-716-U-0-24-00
Key Attributes
Model Number: HEL-716-U-0-24-00
Product Description

Product Overview

The Honeywell HEL-700 Series Thin Film Platinum RTDs (Resistance Temperature Detectors) are engineered for precise temperature monitoring and control in demanding industrial environments. These RTDs offer a linear relationship between resistance and temperature, providing high accuracy, stability, and a wide operating temperature range within a compact, fast-response package. Designed for ready-to-use integration into probe assemblies, they eliminate the need for fragile splices to extension leads. Manufactured with a thin platinum layer on an alumina substrate and laser-trimmed for interchangeability, these RTDs are suitable for a broad spectrum of applications including HVAC, process control, motor windings, medical autoclaves, aircraft, and spacecraft.

Product Attributes

  • Brand: Honeywell
  • Series: HEL-700
  • Construction: Thin film platinum deposited on alumina substrate
  • Package Material: Ceramic (alumina)
  • Leadwire Insulation: TFE Teflon or Fiberglass
  • Leadwire Material: Nickel-coated stranded copper
  • Potting: Epoxy (Teflon-insulated leads) or Ceramic (fiberglass-insulated leads)

Technical Specifications

Characteristic Condition Parameter Value
Alpha R0 = 100 0 C 0.00385 //C
R0 = 1000 0 C 0.00375 //C
Temperature Range TFE Teflon insulated -70 C to 260 C [-94 F to 500 F] -
Fiberglass insulated -75 C to 540 C [-100 F to 1000 F] -
Temperature Accuracy R0 0.2% trim (standard) 0.5 C or 0.8% of temperature, whichever is greater
R0 0.1% trim (optional) 0.3 C or 0.6% of temperature, whichever is greater
Base Resistance & Interchangeability (R0 R0) R0 0.2% trim (standard) 0 C, 1000 2
R0 0.1% trim (optional) 0 C, 1000 1
Linearity -40 C to 125 C 0.1% of full scale
Linearity -75 C to 540 C 2.0% of full scale
Time Constant Water at 3 ft/s 0.086 in O.D. <0.5 s
Still Water 0.086 in O.D. <1.0 s
Operating Current 2 mA max. (1 mA recommended for minimal self-heating)
Stability Occupied environments <0.25 C /year; 0.05 C /5 years
Self Heating 0.086 in O.D. <15 mW/C typ.
Insulation Resistance 50 Vdc at 25 C >50 M
Leadwire Configurations 2-wire, 3-wire
Leadwire Lengths 12 inches standard (custom lengths available via part number)
Models HEL-705, HEL-707, HEL-711, HEL-712, HEL-716, HEL-717

Note: Resistance values R0 are 100 or 1000 . Accuracy tolerance (R1) for 100 RTDs is 1/10th of the value for 1000 RTDs.