Online Service

Online Service

Contact Person
+86 136 6733 2386
quality Precision Temperature Sensor Honeywell HEL-717-U-1-24-C2 Thin Film Platinum RTD with Alumina Substrate factory
<
quality Precision Temperature Sensor Honeywell HEL-717-U-1-24-C2 Thin Film Platinum RTD with Alumina Substrate factory
>
Specifications
Mfr. Part #:
HEL-717-U-1-24-C2
Key Attributes
Model Number: HEL-717-U-1-24-C2
Product Description

Product Overview

The Honeywell HEL-700 Series Thin Film Platinum RTDs are designed for critical temperature monitoring and control in industrial applications. These sensors offer a linear change in resistance versus temperature, providing high linearity, stability, accuracy, and a wide operating temperature range in a compact, fast-response package. Manufactured with a thin layer of platinum on an alumina substrate, they are laser-trimmed for precise interchangeability and come as fully-assembled, ready-to-use elements. Available with TFE Teflon or fiberglass-insulated lead wires, they are suitable for a broad spectrum of industrial, medical, aerospace, and defense applications.

Product Attributes

  • Brand: Honeywell
  • Series: HEL-700
  • Sensing Element: Thin Film Platinum
  • Substrate Material: Alumina
  • Leadwire Insulation: TFE Teflon or Fiberglass
  • Construction: Ceramic case, glassed, wired, and potted/ceramic fired

Technical Specifications

Characteristic Condition Parameter Value (1000 ) Value (100 )
Alpha 0 C 0.00375 //C 0.00375 //C -
0 C - - 0.00385 //C (DIN Standard)
Temperature Range TFE Teflon -70 C to 260 C [-94 F to 500 F] -
Fiberglass -75 C to 540 C [-100 F to 1000 F] -
Temperature Accuracy (Standard Trim 0.2%) R0 0.2% trim 0.5 C or 0.8% of temperature, whichever is greater -
R0 0.1% trim (Optional) 0.3 C or 0.6% of temperature, whichever is greater -
Base Resistance and Interchangeability (R0 R0) 0 C, 0.2% trim (Standard) 2 -
0 C, 0.1% trim (Optional) 1 -
Linearity -40 C to 125 C 0.1% of full scale -
-75 C to 540 C 2.0% of full scale -
Time Constant (Water at 3 ft/s) 0.086 in O.D. <0.5 s -
0.086 in O.D. <1.0 s -
Operating Current Max. 2 mA -
Stability Occupied environments <0.25 C /year; 0.05 C /5 years -
Self Heating Typ. for 0.086 in O.D. <15 mW/C -
Insulation Resistance 50 Vdc at 25 C >50 M -
Case Material - High purity alumina -
Leadwire Material TFE Teflon-insulated Nickel-coated stranded copper, epoxy potting -
Fiberglass-insulated Nickel-coated stranded copper, ceramic potting -

Potential Applications

  • Industrial: HVAC equipment, Instrument and probe assemblies, Process control, Motor windings and bearings, Battery packs, Environmental chambers, Ovens and kilns, Drill holes in large objects
  • Medical: Autoclaves
  • Aerospace/Defense: Aircraft, Space vehicles

Model Configurations (Examples)

Model Series Leadwire Insulation Gauge Wire Count Resistance Alpha Trim Leadwire Length NIST Calibration
HEL-705 TFE Teflon 28 gauge 2-wire 1000 0.00375 //C Standard (0.2%) 12 inches None (00)
HEL-707 Fiberglass 28 gauge 2-wire 100 0.00385 //C Optional (0.1%) 12 inches C1 (at 0 C)
HEL-711 TFE Teflon 28 gauge 3-wire 1000 0.00375 //C Standard (0.2%) 12 inches C2 (at 0 C and 100 C)
HEL-712 Fiberglass 28 gauge 3-wire 100 0.00385 //C Standard (0.2%) 12 inches C3 (at 0 C, 100 C, and 260 C)
HEL-716 TFE Teflon 24 gauge 2-wire 1000 0.00375 //C Optional (0.1%) 12 inches None (00)
HEL-717 Fiberglass 24 gauge 3-wire 100 0.00385 //C Standard (0.2%) 12 inches None (00)

Important Information

CAUTION PRODUCT DAMAGE: Ensure proper ESD (Electrostatic Discharge) precautions are followed when handling this product. Failure to comply with these instructions may result in product damage.

WARNING PERSONAL INJURY: DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.

WARNING MISUSE OF DOCUMENTATION: The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury.