Product Overview
The Honeywell HEL-700 Series Thin Film Platinum RTDs are designed for critical temperature monitoring and control in industrial applications. These sensors offer a linear change in resistance versus temperature, providing high linearity, stability, accuracy, and a wide operating temperature range in a compact, fast-response package. Manufactured with a thin layer of platinum on an alumina substrate, they are laser-trimmed for precise interchangeability and come as fully-assembled, ready-to-use elements. Available with TFE Teflon or fiberglass-insulated lead wires, they are suitable for a broad spectrum of industrial, medical, aerospace, and defense applications.
Product Attributes
- Brand: Honeywell
- Series: HEL-700
- Sensing Element: Thin Film Platinum
- Substrate Material: Alumina
- Leadwire Insulation: TFE Teflon or Fiberglass
- Construction: Ceramic case, glassed, wired, and potted/ceramic fired
Technical Specifications
| Characteristic | Condition | Parameter | Value (1000 ) | Value (100 ) |
|---|---|---|---|---|
| Alpha | 0 C | 0.00375 //C | 0.00375 //C | - |
| 0 C | - | - | 0.00385 //C (DIN Standard) | |
| Temperature Range | TFE Teflon | -70 C to 260 C [-94 F to 500 F] | - | |
| Fiberglass | -75 C to 540 C [-100 F to 1000 F] | - | ||
| Temperature Accuracy (Standard Trim 0.2%) | R0 0.2% trim | 0.5 C or 0.8% of temperature, whichever is greater | - | |
| R0 0.1% trim (Optional) | 0.3 C or 0.6% of temperature, whichever is greater | - | ||
| Base Resistance and Interchangeability (R0 R0) | 0 C, 0.2% trim (Standard) | 2 | - | |
| 0 C, 0.1% trim (Optional) | 1 | - | ||
| Linearity | -40 C to 125 C | 0.1% of full scale | - | |
| -75 C to 540 C | 2.0% of full scale | - | ||
| Time Constant (Water at 3 ft/s) | 0.086 in O.D. | <0.5 s | - | |
| 0.086 in O.D. | <1.0 s | - | ||
| Operating Current | Max. | 2 mA | - | |
| Stability | Occupied environments | <0.25 C /year; 0.05 C /5 years | - | |
| Self Heating | Typ. for 0.086 in O.D. | <15 mW/C | - | |
| Insulation Resistance | 50 Vdc at 25 C | >50 M | - | |
| Case Material | - | High purity alumina | - | |
| Leadwire Material | TFE Teflon-insulated | Nickel-coated stranded copper, epoxy potting | - | |
| Fiberglass-insulated | Nickel-coated stranded copper, ceramic potting | - | ||
Potential Applications
- Industrial: HVAC equipment, Instrument and probe assemblies, Process control, Motor windings and bearings, Battery packs, Environmental chambers, Ovens and kilns, Drill holes in large objects
- Medical: Autoclaves
- Aerospace/Defense: Aircraft, Space vehicles
Model Configurations (Examples)
| Model Series | Leadwire Insulation | Gauge | Wire Count | Resistance | Alpha | Trim | Leadwire Length | NIST Calibration |
|---|---|---|---|---|---|---|---|---|
| HEL-705 | TFE Teflon | 28 gauge | 2-wire | 1000 | 0.00375 //C | Standard (0.2%) | 12 inches | None (00) |
| HEL-707 | Fiberglass | 28 gauge | 2-wire | 100 | 0.00385 //C | Optional (0.1%) | 12 inches | C1 (at 0 C) |
| HEL-711 | TFE Teflon | 28 gauge | 3-wire | 1000 | 0.00375 //C | Standard (0.2%) | 12 inches | C2 (at 0 C and 100 C) |
| HEL-712 | Fiberglass | 28 gauge | 3-wire | 100 | 0.00385 //C | Standard (0.2%) | 12 inches | C3 (at 0 C, 100 C, and 260 C) |
| HEL-716 | TFE Teflon | 24 gauge | 2-wire | 1000 | 0.00375 //C | Optional (0.1%) | 12 inches | None (00) |
| HEL-717 | Fiberglass | 24 gauge | 3-wire | 100 | 0.00385 //C | Standard (0.2%) | 12 inches | None (00) |
Important Information
CAUTION PRODUCT DAMAGE: Ensure proper ESD (Electrostatic Discharge) precautions are followed when handling this product. Failure to comply with these instructions may result in product damage.
WARNING PERSONAL INJURY: DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury.
WARNING MISUSE OF DOCUMENTATION: The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury.
2410311721_Honeywell-HEL-717-U-1-24-C2_C17448795.pdf
Please Use Our Online Inquiry Contact Form Below If You Have Any Questions, Our Team Will Get Back To You As Soon As Possible