The RTY Series and RTP Series Hall-effect Rotary Position Sensors offer non-contact sensing for demanding transportation and industrial environments. The RTY Series features an integral shaft with or without a lever, while the RTP Series separates the magnet from the sensor body for enhanced durability. Both series utilize Hall-effect technology to convert rotary movement into a linear output, housed in a rugged, IP69K-qualified package. They offer multiple operating ranges and voltage options, ensuring versatility for various applications.
Product Attributes
- Brand: Honeywell
- Certifications: CE, UKCA
Technical Specifications
| Characteristic | RTY Series (LV/HV) | RTP Series (LV/HV) |
| Expected life | 35 M cycles | Infinite rotation |
| Air gap (bare magnet actuator) | 3.00 mm 0.5 mm [0.12 in 0.02 in] | |
| Air gap (housed magnet actuator) | 2.00 mm 0.5 mm [0.08 in 0.02 in] | |
| Supply voltage | 5 0.5 Vdc (LV) 10 Vdc to 30 Vdc (HV) | 5 0.5 Vdc (LV) 10 Vdc to 30 Vdc (HV) |
| Supply current (normal) | 20 mA max. (LV) 25 mA max. (HV) | 32 mA max. (LV) 47 mA max. (HV) |
| Output (standard) | 0.5 Vdc to 4.5 Vdc ratiometric | 0.5 Vdc to 4.5 Vdc non-ratiometric |
| Output (inverted) | 4.5 Vdc to 0.5 Vdc ratiometric | 4.5 Vdc to 0.5 Vdc non-ratiometric |
| Output signal delay | 4 ms typ. | 4 ms typ. |
| Overvoltage protection | 10 Vdc (LV) | 10 Vdc (LV) |
| Reverse polarity protection | -10 Vdc (LV) -30 Vdc (HV) | -10 Vdc (LV) -30 Vdc (HV) |
| Output to ground short circuit protection | Continuous | Continuous |
| Resolution | 12 bit | 12 bit |
| Output load resistance (pull down to ground) | 10 kOhm typ. | 10 kOhm typ. |
| EMI radiated immunity | 100 V/m per ISO11452-2 (200 MHz to 1000 MHz) | 100 V/m per ISO11452-2 (200 MHz to 1000 MHz) |
| EMI conducted immunity | 100 mA BCI per ISO11452-4 (1 MHz to 200 MHz) | 100 mA BCI per ISO11452-4 (1 MHz to 400 MHz) |
| Operating temperature range | -40 C to 125 C [-40 F to 257 F] | -40 C to 125 C [-40 F to 257 F] |
| Ingress protection | IP69K | IP69K |
| Shock | 50 G peak | 50 G peak |
| Vibration | 20 G peak | 20 G peak |
| Salt fog concentration | 5% 1% for 240 hr per SAE J1455 | 5% 1% for 240 hr per SAE J1455 |