Specifications
Pressure range:
±1.25Kpa
Function:
Temperature Sensor
Response time:
460us
Mfr. Part #:
HSCDRRN005NDAA5
Package:
DIP-8
Key Attributes
Model Number: HSCDRRN005NDAA5
Product Description

TruStability Board Mount Pressure Sensors - HSC Series

The TruStability High Accuracy Silicon Ceramic (HSC) Series offers highly accurate, compensated, and amplified piezoresistive silicon pressure sensors with a ratiometric analog or digital output. These sensors are designed for reading pressure across a wide range, from 1.6 mbar to 10 bar (160 Pa to 1 MPa, 0.5 inH2O to 150 psi). They are fully calibrated and temperature compensated for offset, sensitivity, thermal effects, and non-linearity by an on-board Application Specific Integrated Circuit (ASIC). The HSC Series is ideal for applications requiring stability, reliability, and industry-leading accuracy, such as in medical devices (ventilators, anesthesia machines) and industrial systems (HVAC, barometry). They are intended for use with non-corrosive, non-ionic gases and can be configured for non-corrosive, non-ionic liquids in specific pressure ranges.

Product Attributes

  • Brand: TruStability
  • Series: HSC Series
  • Technology: Piezoresistive Silicon Ceramic
  • Certifications: ISO 9001 standards, Meets IPC/JEDEC J-STD-020D.1 Moisture Sensitivity Level 1
  • Compliance: REACH and RoHS compliant

Technical Specifications

Characteristic Value Unit Notes
Pressure Range 1.6 mbar to 10 bar mbar, bar See Table 8
Pressure Range 160 Pa to 1 MPa Pa, MPa See Table 9
Pressure Range 0.5 inH2O to 150 psi inH2O, psi See Table 10
Accuracy 0.25 %FSS BFSL %FSS BFSL Full Scale Span Best Fit Straight Line
Compensated Temperature Range 0 C to 50 C C [32 F to 122 F]
Operating Temperature Range -20 C to 85 C C [-4 F to 185 F]
Supply Voltage 3.3 Vdc or 5.0 Vdc Vdc Specified per model
Supply Current 2.1 - 3.5 mA (typical) mA Varies with supply voltage
Output Update Rate ~1 kHz (Analog) / ~2 kHz (Digital) Hz Approximate
Pressure Types Absolute, Gage, Differential See Table 4
Total Error Band (TEB) As specified %FSS See Figure 1 and Tables 8-10
Power Consumption Less than 10 mW (typical) mW
Package Dimensions 10 mm x 10 mm mm Miniature package size
ESD Susceptibility (HBM) 3 kV kV Human Body Model
Storage Temperature -40 C to 85 C C [-40 F to 185 F]