Product Overview
The Honeywell Sensing and Control 40PC Series are miniature, signal-conditioned, amplified pressure sensors designed for applications requiring minimal PCB space. Utilizing silicon piezoresistive technology and a monolithic design, these sensors offer excellent media compatibility and a wide operating temperature range from -45C to +125C. They are ideal for measuring pressure in dry gases only, with port designs accommodating O-ring interfaces.
Product Attributes
- Brand: Honeywell Sensing and Control
- Technology: Silicon Piezoresistive
- Design: Monolithic
- Package: 6 Pin DIP
- Port Interface: Designed for O-ring
Technical Specifications
| Specification | Value |
|---|---|
| General Features | |
| Smallest amplified sensor package | Yes |
| Minimal PCB space | Yes |
| Fully signal conditioned | Yes |
| Operating temperature range | -45 to +125C (-49 to +257F) |
| Storage Temperature | -55 to +125C (-67 to +257F) |
| Accuracy | 0.2% |
| Performance Characteristics | |
| Pressure Range | 50 mm Hg, 0-15 psi, 0-100 psi, 0-150 psi, 0-250 psi |
| Overpressure, max. | 170 mm Hg, 45 psi, 200 psi, 300 psi, 500 psi |
| Supply Voltage | 5 VDC 0.25 |
| Supply Current (max.) | 10 mA |
| Output Source Current (max.) | 0.5 mA |
| Output Sink Current (max.) | 1.0 mA |
| Hysteresis & Repeatability (Typ.) | 0.15% Span |
| Ratiometricity (Typ.) | 0.25% Span (at 4.75 to 5.25 Supply Voltage) |
| Output Load Capacitance (max.) | 0.05 microfarads |
| Full Scale Output Typ. (-50 mm Hg) | 0.50 VDC |
| Full Scale Output Typ. (+50 mm Hg) | 4.50 VDC |
| Full Scale Output Typ. (All other pressure ranges) | 4.50 VDC |
| Media Compatibility | |
| P1 Port | DRY GASES ONLY: Media must be compatible with epoxy based adhesive |
| P2 Port | Media must be compatible with glass, silicon, stainless steel, invar, Sn/Ni plating or Sn/Ag solder |
| Output Performance Characteristics @ 25C, 5VDC (unless otherwise noted) | |
| Pressure Range | Null (VDC) |
| 50 mm Hg | 2.50 |
| 0 to 15 psi | 0.50 |
| 0 to 100 psi | 0.50 |
| 0 to 150 psi | 0.50 |
| 0 to 250 psi | 0.50 |
| Pressure Range | Span (VDC) |
| 50 mm Hg | 4.00 Typ. |
| 0 to 15 psi | 4.00 0.11 |
| 0 to 100 psi | 4.00 0.09 |
| 0 to 150 psi | 4.00 0.07 |
| 0 to 250 psi | 4.00 0.07 |
| Performance Specifications, Temperature/Accuracy | |
| Temperature Range | Total Accuracy (% Span) Max. |
| 25C | 0.4 (RSS) for 0-15 psi; 0.2 (RSS) for 0-100, 0-150, 0-250 psi |
| -18 to +63C | 4.0 for 0-15 psi; 2.5 for 0-100, 0-150 psi; 2.0 for 0-250 psi |
| -45 to +85C | 4.0 for 0-15 psi; 2.5 for 0-100, 0-150 psi; 2.0 for 0-250 psi |
| -45 to +125C | 3.0 for 0-15 psi; 2.5 for 0-100, 0-150 psi; 3.0 for 0-250 psi |
| Electrical Connection Notes | |
| Pin 1 Indicator | Square corner mark (Vs) |
| Output Protection | Short circuit protected |
| 40PC Series Order Guide (Examples) | |
| Catalog Listing | Pressure Range |
| 40PC001B1A | 50 mm Hg |
| 40PC015G1A | 0-15 psi |
| 40PC100G1A | 0-100 psi |
| 40PC150G1A | 0-150 psi |
| 40PC250G1A | 0-250 psi |
| Lead Style | Description |
| 1 | unformed |
| 2 | formed away from port |
| 3 | formed towards port |
| Pressure Type | Description |
| B | Bi-directional |
| G | Gage |