Product Overview
The RTY Series and RTP Series Hall-effect Rotary Position Sensors offer non-contact sensing for demanding transportation and industrial applications. The RTY Series features an integral shaft with or without a lever, while the RTP Series separates the magnet from the sensor body for enhanced durability. Both series utilize a magnetically biased Hall-effect IC to convert rotary actuator movement into a linear output, sealed in a rugged, IP69K-qualified package. They support eight operating ranges from 50 to 360 and are available in low and high voltage versions.
Product Attributes
- Brand: Honeywell
- Technology: Hall-effect
- Certifications: CE
- Protection: IP69K-qualified, Automotive-grade EMI/EMC testing, integrated reverse polarity, and short circuit protection
Technical Specifications
| Characteristic | RTY Series (LV/HV) | RTP Series (LV/HV) |
| Expected life | 35 M cycles | Infinite rotation |
| Air gap: bare magnet actuator | 3,00 mm 0.5 mm [0.12 in 0.02 in] | |
| Air gap: housed magnet actuator | 2,00 mm 0.5 mm [0.08 in 0.02 in] | |
| Material: shaft | stainless steel | |
| Material: magnet | NdFeB | |
| Material: sensor housing | PBT plastic | PBT plastic |
| Material: housed magnet overmold | PPS plastic | |
| Material: sensor/housed magnet bushing | brass | brass |
| Material: sensor bushing | stainless steel | stainless steel |
| Mating connector | AMP Superseal 282087-1 | AMP Superseal 282087-1 |
| Supply voltage | 5 0.5 Vdc (LV) 10 Vdc to 30 Vdc (HV) | 5 0.5 Vdc (LV) 10 Vdc to 30 Vdc (HV) |
| Supply current (normal) | 20 mA max. (LV) 25 mA max. (HV) | 32 mA max. (LV) 47 mA max. (HV) |
| Supply current (output to ground short) | 20 mA max. (LV) 25 mA max. (HV) | 32 mA max. (LV) 47 mA max. (HV) |
| Output: standard | 0.5 Vdc to 4.5 Vdc ratiometric | 0.5 Vdc to 4.5 Vdc ratiometric |
| Output: inverted | 4.5 Vdc to 0.5 Vdc ratiometric | 4.5 Vdc to 0.5 Vdc ratiometric |
| Output: standard (non-ratiometric) | 0.5 Vdc to 4.5 Vdc non-ratiometric | |
| Output: inverted (non-ratiometric) | 4.5 Vdc to 0.5 Vdc non-ratiometric | |
| Output signal delay | 4 ms typ. | 4 ms typ. |
| Overvoltage protection | 10 Vdc (LV) (HV) | 10 Vdc (LV) (HV) |
| Reverse polarity protection | -10 Vdc (LV) -30 Vdc (HV) | -10 Vdc (LV) -30 Vdc (HV) |
| Output to ground short circuit protection | continuous | continuous |
| Resolution | 12 bit | 12 bit |
| Output load resistance (pull down to ground) | 10 kOhm typ. | 10 kOhm typ. |
| EMI radiated immunity | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz | 100 V/m per ISO11452-2 from 200 MHz to 1000 MHz |
| EMI conducted immunity | 100 mA BCI per ISO11452-4 from 1 MHz to 200 MHz | 100 mA BCI per ISO11452-4 from 1 MHz to 400 MHz |
| Operating temperature range | -40 C to 125 C [-40 F to 257 F] | -40 C to 125 C [-40 F to 257 F] |
| Ingress protection | IP69K | IP69K |
| Media compatibility | heavy transportation fluids | heavy transportation fluids |
| Shock | 50 G peak (excluding RTY sensor shaft with lever) | 20 G peak |
| Vibration | 20 G peak (excluding RTY sensor shaft with lever) | 20 G peak |
| Salt fog concentration | 5% 1% for 240 hr per SAE J1455 Section 4.3.3.1 (at 5.0 Vdc, 38 C [100 F ]) | bare magnet: 96 hr for as per ASTM B117 housed magnet: 240 hr per ASTM B117 |